IN recent times technical advances in other areas of surgery, and the encouraging results following operation on relatively large vessels, have reawakened an interest in corrective surgery on small vessels, particularly those of critical organs. Successful anastomosis, using standard techniques, was
Mechanical properties of fibrin adhesives for blood vessel anastomosis
β Scribed by Flahiff, C. ;Feldman, D. ;Saltz, R. ;Huang, S.
- Publisher
- John Wiley and Sons
- Year
- 1992
- Tongue
- English
- Weight
- 692 KB
- Volume
- 26
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
Various methods have been used for anastomosing, or attaching, two ends of a severed blood vessel together. The most common method, suturing, is tedious, can be time-consuming, and requires special training in microvascular surgery. Other methods, such as mechanical devices and lasers, have some problems as well. The use of fibrin adhesives for blood vessel anastomosis might eliminate some of the current problems by allowing a quicker, simpler, and more reliable method of attachment. Although mechanical studies have been conducted to determine fibrin glue properties in shear, tensile, and burst tests; most of these studies have used skin or intestinal tissue. Therefore, to evaluate the feasibility of using fibrin glue as an adhesive for blood vessel anastomosis, the mechanical properties of blood vessels joined with fibrin glue were examined using tensile and burst tests. High and low fibrinogen concentrations were tested after 5-or 45-min time periods. In addition, three clinical methods of attachment were compared: end-to-end anastomosis, vessel overlapping, and suturing. In this study, because the adhesive strength was not found to increase significantly after 5 min, setting times for fibrin glue may be short enough to make it a clinical option when compared to suturing. In addition, the higher fibrinogen concentration did not result in a significantly higher adhesive strength, indicating that the lower concentration fibrin adhesives may be of comparable strength to the higher concentrations for clinical applications.
π SIMILAR VOLUMES
A testing method was developed to evaluate the mechanical properties of a fibrin adhesive in an effort to correlate mechanical strength to fibrinogen content. Autologous fibrin adhesives with varying fibrinogen content were loaded to failure in shear using a mechanical testing machine. The method de
A new technique is introduced in which an argon laser coagulates blood to form an adherent sleeve for the anastomosis of small vessels. The argon laser solidifies the blood into a dark tensile substance which supports the site of repair until vascular continuity is achieved. Laser pulses of 0.75 W a
## Abstract Calcium phosphate cement (CPC) that can be injected to form a scaffold in situ has promise for the repair of bone defects. However, its lowβstrength limits the CPC to nonβstressβbearing repairs. Fibrin glue (FG) with good sticking property and biocompatibility is possible used to reinfo
The improved adhesion of an ultrahigh molecular weight polyethylene (UH-MWPE) fiber to an epoxy from applying polypyrrole (PPy) was investigated using chemical oxidation polymerization. The interfacial shear strength of the PPy-treated fiber/epoxy was enhanced by 280%. Such an improvement was verifi