𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measurement of total and diffusible serum fluoride

✍ Scribed by Alfredo Rigalli; Rosa Alloatti; Rodolfo C. Puche


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
89 KB
Volume
13
Category
Article
ISSN
0887-8013

No coin nor oath required. For personal study only.

✦ Synopsis


This article describes a technique for the measurement of total and diffusible F content of serum, at clinical significant concentrations of F (1-10 Β΅M). The proposed procedure avoids the interference of unknown serum components with the ion-specific electrode. Sample F is concentrated fivefold through distillation of hydrofluoric acid (Taves' method). Ionic fluoride is presented to the electrode in a simple solution at concentrations within the linear response of the electrode. Average recoveries of F from serum or its ultrafiltrate were 96 Β± 7% (21%) and 97 Β± 12% (53%) (mean Β± SEM [CV]), respectively. With four replicates of each sample, the technique produce withinrun standard deviations of 0.6 Β΅M and 2.2 Β΅M at 1 and 10 Β΅M F, respectively. Total precision assessment gave standard deviations of 0.6 Β΅M and 2.6 Β΅M at 1 and 10 Β΅M F, respectively. The fasting serum F levels of normal climacteric women, 45 to 65 years, showed an asymmetric distribution. The data obtained started at the detection limit of the technique (0.1 mM). The 75 percentile was 1.85 Β΅M for total and 0.5 Β΅M for diffusible F. In patients (n = 25) treated with NaF (30 mg F/day) the fasting levels of total serum F (4.5 Β± 1.7 Β΅M) did not differ from those of diffusible F (4.2 Β± 1.5 Β΅M). In patients (n = 50) treated with sodium monofluorophosphate (15 mg F/day) the fasting levels of total and diffusible serum F were 6.5 Β± 1.7 Β΅M and 0.5 Β± 0.03 Β΅M, respectively.In conclusion, this paper establishes the presence of two fractions of serum fluorine: diffusible and nondiffusible (or protein bound) and describes a technique for their clinical estimation. In untreated subjects and in patients receiving NaF, the former fraction contains ionic fluoride. In patients treated with MFP, diffusible serum fluorine is composed by ionic fluoride and low molecular weight, peptide-bound, acid-labile fluorine.


πŸ“œ SIMILAR VOLUMES


Simultaneous automated measurement of se
✍ Dr. Yoshinori Uji; Arthur Karmen; Hiroyuki Sugiuchi; Hiroaki Okabe; Keishi Hata; πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 294 KB

## Abstract We automated a two‐step kinetic procedure for determining serum CK‐MM isoform ratio using an immunoinhibition method. By measuring the total CK activity and the residual CK activity (serum CK‐MM isoform) remaining after the inhibition by tissue CK‐MM isoform specific monoclonal antibody

Rapid measurement of serum pancreatic am
✍ Michael Landt; Glen L. Hortin; Carl H. Smith; Gail Pashos; Hemant C. Vaidya; Jer πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 604 KB

A simple, rapid assay for the pancreatic isoenzyme of human serum amylase was developed. The assay utilized an immunoabsorbent prepared by coating latex beads with a monoclonal antibody specific for pancreatic amylase.Treatment of patient serum with immunoabsorbent removed pancreatic amylase, and me

Influence of garlic on serum cholesterol
✍ Bakhsh, Rasool ;Chughtai, M. I. D. πŸ“‚ Article πŸ“… 1984 πŸ› John Wiley and Sons 🌐 English βš– 238 KB

Human subjects were used for a garlic experiment. The subjects were given a fat-rich diet for 7 days and on the 8th day the fasting blood was analyzed for serum cholesterol, serum triglycerides, serum total lipids and serum glucose. The human subjects were then given a fat-rich diet with 40 g of gar

The validation of freely diffusible trac
✍ Jeffrey J. Neil πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 387 KB

While the general theory of measuring organ perfusion using exogenously administered freely diffusible tracers was originally formulated over 40 years ago, the application of NMR techniques for tracer detection is a recent development. A brief theoretical review and discussion of the literature vali

Specific heat and thermal diffusivity of
✍ Y. W. Wong; N. M. Hui; E. L. Ong; H. L. W. Chan; C. L. Choy πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 118 KB

## Abstract The specific heat (__C__) and thermal diffusivity (__D__) of vinylidene fluoride (VDF)/trifluoroethylene copolymers with 70 and 56 mol % of VDF were measured between 200 and 390 K, and the thermal conductivity (__K__) was calculated from these data. __C__, __D__, and __K__ were rather i