The ionization of nucleosides in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was systematically investigated using adenine (A), thymine (T), guanine (G) and cytosine (C) with several common matrices. Experimental results of the protonation and deprotonation of the ba
Measurement of polymorphic trinucleotide repeats in the androgen receptor gene by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
โ Scribed by Wada, Yoshinao; Mitsumori, Kenji; Terachi, Toshiro; Ogawa, Osamu
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 76 KB
- Volume
- 34
- Category
- Article
- ISSN
- 1076-5174
No coin nor oath required. For personal study only.
โฆ Synopsis
Trinucleotide repeats are polymorphic in normal individuals. CAG repeats in the X-linked androgen receptor gene were counted by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS). A region of approximately two hundred base-pairs containing the repeats was amplified by polymerase chain reaction, then measured after a simple purification procedure. The single-charged molecular ion species was detected using 0.1 pmol of DNA sample and the number of repeats was determined from the molecular mass. The results indicated that MALDI/TOF-MS is a high-throughput alternative to polyacrylamide gel electrophoresis for precise determination of polymorphic trinucleotide repeats.
๐ SIMILAR VOLUMES
Oligonucleotide sequencing by fragmentation in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry has been demonstrated. With this sequencing method, the preparation of oligonucleotide ladder products and gel electrophoresis are not required, thus the sequencing
The limits of performance of a linear time-of-flight mass spectrometer using matrix-assisted laser desorp tionlionization have been tested. Effects of the pressure in the vacuum system and the sampling rate of the digital oscilloscopes on mass resolution have been investigated. Spectra recorded at d
The time-of-flight effect in Fourier transform mass spectrometry (FTMS) with an external ion source was quantified. The time-of-flight profiles of ions of different masses were measured by stepping the time interval between the ionization pulse and the gating of the trapping voltage (T gate ). The o
Comparative studies of the matrix-assisted laser desorption/ionization (MALDI) of 30 antibiotics were made using a-cyano-4-hydroxycinnamic acid (HCCA), 2,5-dihydroxybenzoic acid (DHB), 5,10,15,20tetrakis(4-hydroxyphenyl)-21H,23H-porphyrin and meso-tetra(N-methyl-4-pyridyl)porphyrin matrices. Most an