𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measurement of muscle protein fractional synthetic rate by capillary gas chromatography/combustion isotope ratio mass spectrometry

✍ Scribed by Kevin E. Yarasheski; Kenneth Smith; Michael J. Rennie; Dennis M. Bier


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
523 KB
Volume
21
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Determination of low isotopic enrichment
✍ Reijngoud, Dirk-Jan; Hellstern, Gerald; Elzinga, Henk; de Sain-van der Velden, M πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 225 KB πŸ‘ 2 views

A method was developed for measuring protein fractional synthetic rates using the N-methoxycarbonylmethyl ester (MCM) derivative of L-[ 1-13C ] valine and on-line gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The derivatization procedure can be performed rapidly and GC s

Analysis of exogenous dehydroepiandroste
✍ Makoto Ueki; Masato Okano πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 96 KB πŸ‘ 2 views

A detailed procedure for the analysis of exogenous dehydroepiandrosterone (DHEA) in urine by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) has been established for detecting doping with DHEA. The average d -value (parts per thousand difference of 13 C/ 12 C ratio from the

Measurement of deuterium incorporation i
✍ C. M. Scrimgeour; I. S. Begley; M. L. Thomason πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 47 KB πŸ‘ 2 views

A continuous-flow pyrolysis interface for gas chromatography/isotope ratio mass spectrometry (GC/IRMS) has been developed for 2 H analysis of individual organic compounds. Pyrolysis of gas chromatographically separated fatty acid methyl esters is performed at 1200 Β°C in an unpacked alumina tube to c

Improved method of detection of testoste
✍ Aguilera, Rodrigue; Becchi, Michel; Casabianca, HervΓ©; Hatton, Caroline K.; Catl πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 665 KB

The current approach to detection of doping with testosterone is based on measuring the testosterone to epitestosterone ratio (T/E) in urine by gas chromatography/mass spectrometry. The median T/E for healthy males who have not used T is about 1.0. In a single urine, a T/E lower than six leads to a

Characterization of exogenous testostero
✍ VΓ©ronique Ferchaud; Bruno Le Bizec; Fabrice Monteau; FranΓ§ois Andre πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 79 KB πŸ‘ 2 views

The detection of exogenous testosterone in bovine urine was investigated by using gas chromatography/ combustion/isotope ratio mass spectrometry (GC/C/IRMS). The carbon isotopic ratio measurement of epitestosterone, etiocholanolone (testosterone metabolite) and DHEA (testosterone precursor) in femal