Expernnents were carried out m a stirred cell with a flat gas-hqmd interface to test the Danckwerts' plot method of measuring effective mterfaclal area A and physical mass transfer co&clent kL Pure CO, was absorbed into an aqueous solution of 0 5 mol Na,CO, + 0 5 mol NaHCO, per liter, m the presence
Measurement of interfacial area in a packed column by the sulfite oxidation method. Comparison with the wetted area
✍ Scribed by J. Andrieu; B. Claudel
- Publisher
- Elsevier Science
- Year
- 1974
- Tongue
- English
- Weight
- 639 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0009-2509
No coin nor oath required. For personal study only.
✦ Synopsis
Interfacial area of a column packed with Raschig rings, 10 mm in diameter, is measured by the classical sulfite oxidation method. It is shown that the column behaves as a recycle differential reactor. Values of the interfacial area are compared, on the one hand with those obtained by Vidwans and Sharma under similar conditions, on the other hand with the results previously obtained by ourselves on the same packing by wetted area measurements. Good agreement is observed in either case.
📜 SIMILAR VOLUMES
Values of the liquid-side mass transfer coefficient, kL and the interfacial area, a per unit volume of froth on a sieve plate (perforated area 55%) were found using the technique of absorption accompanied by irreversible pseudo-first order reaction. The experiments were carried out with several reac