New methods are presented for measuring total vitamin C and the ascorbic acid/dehydroascorbic acid ratio in gastric juice. Extracts are prepared from a gastric juice which are suitable for direct injection onto a Waters Nova-pak C , , Radial-pak cartridge for high performance liquid chromatography (
Measurement of ascorbic acid and dehydroascorbic acid in mammalian tissue utilizing HPLC and electrochemical detection
β Scribed by Debra A. Schell; Ann M. Bode
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 644 KB
- Volume
- 7
- Category
- Article
- ISSN
- 0269-3879
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Reliable measurement of the reduced and oxidized forms of ascorbic acid (AA) is challenging because they are highly reactive and unstable compounds. Detection of small amounts of AA and dehydroascorbic acid (DHAA) is essential for determining the biochemical function of the vitamin. While a variety of techniques exist for measurement of AA with detection limits in the millimolar range, a need exists for highly reliable assessment of picomolar levels of AA and DHAA in tissues. The present study presents a method for measuring AA and DHAA that combines high performance liquid chromatography with the advantages and increased detection limits and selectivity available with coulometric electrochemical detection. The difference between AA and βtotal AAβοΈ in tissue samples gives an assessment of DHAA concentration. Verification of the reliability of assay is by the successful linear recovery of exogenously added AA and DHAA in tissue homogenate. Optimal conditions for reducing DHAA in tissue samples include a pH of 7.2, reaction time of 10 min, reaction temperature equal to room temperature, and a 10 mM concentration of the reducing agent, Ξ²βmercaptoethanol. AA and DHAA are measured in several mammalian tissues using the method presented.
π SIMILAR VOLUMES
A postcolumn reactor which reduces dehydroascorbic acid to ascorbic acid for use in high-performance liquid chromatography is described. This reactor permits the direct determination of both ascorbic and dehydroascorbic acids after their chromatographic separation. 1993 Academic Press, Inc.