𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measurement of acetol in serum

✍ Scribed by Joseph P. Casazza; Janet L. Fu


Publisher
Elsevier Science
Year
1985
Tongue
English
Weight
423 KB
Volume
148
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


A method for the derivatization of acetol (I-hydroxyacetone) with 2,4-dinitrophenylhydrazine (DNPH) and for the measurement of the acetol dinitrophenylhydrazone derivative (acetol-DNPH) by high-performance liquid chromatography is presented. The chromatographic separation described here resulted in baseline resolution of the acetol-DNPH peak. Peak integration was proportional to serum acetol concentration over a 5-to 500~nmol/ml range. No other method for the determination of acetol in serum currently exists. Serum from rats in diabetic ketoacidosis was found to contain 11.2 + 1.1 nmol acetol/ml serum (N = 3). Serum from a 21-day-fasted human contained 16 nmol/ml acetol. Serum from rats maintained on drinking water containing 1% acetone (v:v) for 6 days contained 152 + 31 nmol/ml acetol (N = 5). The presence of acetol in serum under conditions where acetoacetate and acetone are chronically elevated suggests that acetoacetate may be converted to glucose through the conversion of acetone to acetol and L-1,2-propanediol.


πŸ“œ SIMILAR VOLUMES


Rapid measurement of serum pancreatic am
✍ Michael Landt; Glen L. Hortin; Carl H. Smith; Gail Pashos; Hemant C. Vaidya; Jer πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 604 KB

A simple, rapid assay for the pancreatic isoenzyme of human serum amylase was developed. The assay utilized an immunoabsorbent prepared by coating latex beads with a monoclonal antibody specific for pancreatic amylase.Treatment of patient serum with immunoabsorbent removed pancreatic amylase, and me

Measurement of total and diffusible seru
✍ Alfredo Rigalli; Rosa Alloatti; Rodolfo C. Puche πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 89 KB

This article describes a technique for the measurement of total and diffusible F content of serum, at clinical significant concentrations of F (1-10 Β΅M). The proposed procedure avoids the interference of unknown serum components with the ion-specific electrode. Sample F is concentrated fivefold thro

Simultaneous automated measurement of se
✍ Dr. Yoshinori Uji; Arthur Karmen; Hiroyuki Sugiuchi; Hiroaki Okabe; Keishi Hata; πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 294 KB

## Abstract We automated a two‐step kinetic procedure for determining serum CK‐MM isoform ratio using an immunoinhibition method. By measuring the total CK activity and the residual CK activity (serum CK‐MM isoform) remaining after the inhibition by tissue CK‐MM isoform specific monoclonal antibody

A new immunoassay for the measurement of
✍ Dr. P. Carraro; M. Plebani; M. C. Varagnolo; M. Zaninotto; M. Rossetti; A. Burli πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 437 KB

Because the concentration of serum myoglobin (Mb) increases within 2 to 4 hours after the first sign of acute myocardial infarction, it has been proposed as an early marker of the condition. Our aim was to evaluate a new assay that provides a rapid, quantitative determination of Mb (Baxter Stratus M