The high-temperature Knudsen effusion method was used to study the vaporization processes in the DyF,-Dy,O, system at 1357i5 K. The following ions were identified in the mass spectra of the vapour over the system studied: DyF;, DyF,', DyF', Dy+, DyOF', DyO' as well as insignificant quantities of the
โฆ LIBER โฆ
Mass spectrometric study of processes in the closed tube vapor growth of CdS and ZnS
โ Scribed by V.S. Ban; E.A.D. White
- Publisher
- Elsevier Science
- Year
- 1976
- Tongue
- English
- Weight
- 287 KB
- Volume
- 33
- Category
- Article
- ISSN
- 0022-0248
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
High-temperature Mass Spectrometric Stud
โ
V. L. Stolyarova; S. Seetharaman
๐
Article
๐
1996
๐
John Wiley and Sons
๐
English
โ 822 KB
A high-temperature mass spectrometric st
โ
V. L. Stolyarova; S. Seetharaman; D. Svard; G. A. Semenov
๐
Article
๐
1998
๐
John Wiley and Sons
๐
English
โ 234 KB
๐ 2 views
The high-temperature Knudsen effusion method was used to study the vaporization processes and thermodynamic properties of fluxes based on CaO-CaCl 2 and CaO-CaF 2 systems with additions of Al, Al 2 O 3 in the temperature range 800-2240 K. The composition of vapour and the partial pressures of vapour
Mass spectrometric and thermodynamic stu
๐
Article
๐
1973
๐
Elsevier Science
๐
English
โ 503 KB