𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Mass spectrometric determinations of the absolute tritium activities of NBS tritiated water standards

✍ Scribed by B.M. Oliver; M.M. Bretscher; Harry Farrar IV


Publisher
Elsevier Science
Year
1989
Weight
656 KB
Volume
40
Category
Article
ISSN
0883-2889

No coin nor oath required. For personal study only.

✦ Synopsis


The tritium content of U.S. National Bureau of Standards tritiated water Standard Reference Materials SRM-4926, -4926C and -4927B have been measured by mass spectrometry, where the accumulation of 3He from tritium decay is measured as a function of time. The averaged results, which are compared with other independent calibrations, are 0.7% higher than the NBS certified values and have an uncertainty (la) of 0.4%. Additionally, the half life of tritium has been determined from new calculations of the average energy of tritium decay, combined with existing measurements of the tritium decay energy emission rate. The new half life value, 12.38+0.04y, is essentially the same as the 12.38 _+ 0.03 ~ value recently obtained mass spectrometrically with the same analysis system used in the present measurements.


πŸ“œ SIMILAR VOLUMES


Tandem Mass Spectrometric Assay for the
✍ Armin Rettinger; Klaus Gempel; Sabine Hofmann; Klaus-Dieter Gerbitz; Matthias F. πŸ“‚ Article πŸ“… 2002 πŸ› Elsevier Science 🌐 English βš– 76 KB

Carnitine palmitoyltransferase II (CPT-II) mediates the import of long-chain fatty acids into the mitochondrial matrix for subsequent ␀-oxidation. Defects of CPT-II manifest as a severe neonatal hepatocardiomuscular form or as a mild muscular phenotype in early infancy or adolescence. CPT-II deficie

Vacuum fusion-mass spectrometric determi
✍ T.J. Shultz; H.M. Adams; L.M. Green πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 705 KB

A vacuum fusion-mass spectrometric method is described for the determination of H, N and 0 in uranium silicide fuels. Samples are fused with an 85% Pt/lS% Sn flux in a graphite crucible heated to 1300Β°C to release nitrogen and oxygen as N, and CO, respectively. Hydrogen evolves more readily and is d

Evaluation of Flow Injection Sample to S
✍ Coedo, A. G.; Dorado, M. T.; Ruiz, J.; Escudero, M.; Rubio, J. C. πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 607 KB

An on-line flow injection sample to standard addition method was developed for the determination of aluminium in biological tissues by inductively coupled plasma mass spectrometry. The sample concentration is calculated from two transient signals obtained from the injection of the blank and the samp

Development of an analytical method for
✍ Markus Himmelsbach; Christian W. Klampfl; Wolfgang Buchberger πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 293 KB πŸ‘ 1 views

## Abstract A method for the quantitative determination of major antidepressants in aqueous matrices by CE using ESI‐MS is presented. Several aqueous, nonaquoeus, and mixed aqueous/organic solvent BGEs including inorganic and organic acids were investigated with respect to their suitability for the

Gas chromatographic mass spectrometric d
✍ A. Gerardin; D. Gaudry; D. Wantiez πŸ“‚ Article πŸ“… 1982 πŸ› John Wiley and Sons 🌐 English βš– 300 KB πŸ‘ 2 views

A method for the quantitative determination of 1,2,3-propanetrioltrinitrate (nitroglycerin) in human plasma by gas chromatography mass spectrometry has been developed. After addition of 1,2,3propanetriol(I5N)trinitrate as internal standard, plasma (1 ml) is extracted by a mixture of pentane and meth