𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Magnetic resonance imaging of ultrasonic fields

✍ Scribed by C.L. Walker; F.S. Foster; D.B. Plewes


Publisher
Elsevier Science
Year
1998
Tongue
English
Weight
623 KB
Volume
24
Category
Article
ISSN
0301-5629

No coin nor oath required. For personal study only.

✦ Synopsis


A nuclear magnetic resonance imaging (MRI) method is described that allows noninvasive, quantitative mapping of medical ultrasound (US) fields in tissue. Application of a resonant magnetic field gradient operating at the US frequency permits detection of nanometer motions associated with ultrasound, and allows direct measurement of absolute pressure, intensity, and speed of sound. By altering gradient timing, the propagation of US fields in time and space can be observed; this enables tracking of US scattering phenomena in a tissue-equivalent medium. An experimental apparatus was constructed that combined a 515-kHz focused US transducer configured with its focus in the center of a small-bore oscillating gradient. This provided an oscillating gradient with a peak gradient strength of 0.40 T/m over a useable imaging volume of 61 cm3. When used in conjunction with 1.5-T clinical MRI system, this apparatus allowed the clear visualization of the focused US field within this volume and its propagation with time. Current limits of sensitivity indicate a noise equivalent sensitivity of 3.8 nm in displacement amplitude, 19 kPa in pressure amplitude and 12 mW/cm2 in acoustic intensity. These studies indicate that MRI can provide a new, noninvasive method for US exposimetry and the basic study of ultrasound biophysics in tissue.


πŸ“œ SIMILAR VOLUMES


Magnetic resonance imaging of ultrasound
✍ D.B. Plewes; S. Silver; B. Starkoski; C.L. Walker πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 172 KB πŸ‘ 1 views

Phase-contrast magnetic resonance imaging (MRI) is used to image particle displacements arising from a 0.515-MHZ focused ultrasound (US) field. The technique used a phase-locked, self-resonant gradient matched to the US frequency in conjunction with a spin-echo sequence to generate phase images of U

Lack of mutagenic and co-mutagenic effec
✍ Wolfgang G. Schreiber; Elke M. Teichmann; Ilka Schiffer; Jochem Hast; Wahida Akb πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 155 KB πŸ‘ 1 views

## Abstract Mutagenic and co‐mutagenic effects of static, pulsed bipolar gradient, and high‐frequency magnetic fields, as well as combinations of them, were examined using the Ames test. The Ames test using __Salmonella typhimurium__ bacteria, wild‐type strain RTA, preincubation assay, without meta