Magnetic resonance imaging of ultrasound fields: Gradient characteristics
β Scribed by D.B. Plewes; S. Silver; B. Starkoski; C.L. Walker
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 172 KB
- Volume
- 11
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
β¦ Synopsis
Phase-contrast magnetic resonance imaging (MRI) is used to image particle displacements arising from a 0.515-MHZ focused ultrasound (US) field. The technique used a phase-locked, self-resonant gradient matched to the US frequency in conjunction with a spin-echo sequence to generate phase images of US-induced displacement parallel to the US propagation direction. The gradient design was numerically optimized to provide maximum linearity and magnitude while minimizing gradient inductance. The windings were fabricated of Litz wire to minimize resistive losses and mounted in an oil-cooled imaging chamber. When driven by a resonance power supply, a peak magnetic field gradient of 0.40 T/m was attained with a peak current of 20 amp in a volume of 53 cm(3), achieving stable oscillation at the required US frequency. Clear detection of the nanometer scale particle motions of the US field was achieved and allowed quantitative, noninvasive visualization of the entire US field. While the required gradient slew rate for US detection is beyond that recommended for in vivo application, this imaging method opens new possibilities for in vitro or ex vivo research in the study of the interaction of US with tissue.
π SIMILAR VOLUMES
## Abstract The tradeoff between gradient performance factors, size of the imaging region, and physiological factors such as nerve stimulation typically leads to compromises in gradient design and ultimately suboptimal imaging performance. Local gradient systems can add some performance flexibility
A modified spiral imaging technique is presented, in which the allowing easier implementation on scanner hardware (8). conventional sinusoidal gradient waveforms are replaced by trape-The current gradient waveform provides the desired reduczoidal ones. In addition to allowing a reduced data acquisit
## Abstract Mutagenic and coβmutagenic effects of static, pulsed bipolar gradient, and highβfrequency magnetic fields, as well as combinations of them, were examined using the Ames test. The Ames test using __Salmonella typhimurium__ bacteria, wildβtype strain RTA, preincubation assay, without meta