Magnetic resonance imaging of ultrasound fields: Gradient characteristics

✍ Scribed by D.B. Plewes; S. Silver; B. Starkoski; C.L. Walker


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
172 KB
Volume
11
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Phase-contrast magnetic resonance imaging (MRI) is used to image particle displacements arising from a 0.515-MHZ focused ultrasound (US) field. The technique used a phase-locked, self-resonant gradient matched to the US frequency in conjunction with a spin-echo sequence to generate phase images of US-induced displacement parallel to the US propagation direction. The gradient design was numerically optimized to provide maximum linearity and magnitude while minimizing gradient inductance. The windings were fabricated of Litz wire to minimize resistive losses and mounted in an oil-cooled imaging chamber. When driven by a resonance power supply, a peak magnetic field gradient of 0.40 T/m was attained with a peak current of 20 amp in a volume of 53 cm(3), achieving stable oscillation at the required US frequency. Clear detection of the nanometer scale particle motions of the US field was achieved and allowed quantitative, noninvasive visualization of the entire US field. While the required gradient slew rate for US detection is beyond that recommended for in vivo application, this imaging method opens new possibilities for in vitro or ex vivo research in the study of the interaction of US with tissue.


πŸ“œ SIMILAR VOLUMES


Electron Paramagnetic Resonance Imaging
✍ Keiichi Ohno; Masakazu Watanabe πŸ“‚ Article πŸ“… 2000 πŸ› Elsevier Science 🌐 English βš– 269 KB

A novel X-band CW EPR imaging has been developed using magnetic-field-gradient (MFG) spinning to obtain spatial distributions of electron paramagnetic species. Spinning MFG EPR imaging for 65 projection spectra required just 55 s while conventional imaging took 11 min 40 s, that is, the acquisition

Magnetic resonance imaging with composit
✍ Dennis L. Parker; K. Craig Goodrich; J. Rock Hadley; Seong-Eun Kim; Sung M. Moon πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 159 KB πŸ‘ 1 views

## Abstract The tradeoff between gradient performance factors, size of the imaging region, and physiological factors such as nerve stimulation typically leads to compromises in gradient design and ultimately suboptimal imaging performance. Local gradient systems can add some performance flexibility

Fast Spiral Magnetic Resonance Imaging w
✍ Jeff H. Duyn; Yihong Yang πŸ“‚ Article πŸ“… 1997 πŸ› Elsevier Science 🌐 English βš– 296 KB

A modified spiral imaging technique is presented, in which the allowing easier implementation on scanner hardware (8). conventional sinusoidal gradient waveforms are replaced by trape-The current gradient waveform provides the desired reduczoidal ones. In addition to allowing a reduced data acquisit

Lack of mutagenic and co-mutagenic effec
✍ Wolfgang G. Schreiber; Elke M. Teichmann; Ilka Schiffer; Jochem Hast; Wahida Akb πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 155 KB πŸ‘ 1 views

## Abstract Mutagenic and co‐mutagenic effects of static, pulsed bipolar gradient, and high‐frequency magnetic fields, as well as combinations of them, were examined using the Ames test. The Ames test using __Salmonella typhimurium__ bacteria, wild‐type strain RTA, preincubation assay, without meta