Magnetic resonance imaging of periosteum with ultrashort TE pulse sequences

โœ Scribed by Ines L.H. Reichert; Michael Benjamin; Peter D. Gatehouse; Karyn E. Chappell; Joanne Holmes; Taigang He; Graeme M. Bydder


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
506 KB
Volume
19
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

Purpose

To assess the values of pulse sequences with ultrashort echo times (0.08 msec) for detecting and characterizing periosteum.

Materials and Methods

Two normal volunteers aged 33 and 58 years and 12 patients aged seven to 55 years were studied. A total of 10 of the patients had contrast enhancement with intravenous Gadodiamide. Two ovine tibias were examined before and after the periosteum was stripped from the bone.

Results

High signal regions were observed adjacent to cortical bone in all parts of the skeleton imaged. They were generally more conspicuous after fat suppression and contrast administration. In the ovine tibia there was a reduction in the high signal normally seen at the surface of the bone after periosteal stripping. The detached periosteum produced a high signal. Mean T~2~* values for adult human periosteum ranged from 5.3 to 11.4 msec. After enhancement the signal intensity increased. In two patients with tibial fractures, increased periosteal signal was seen and this showed marked enhancement. Signals from periosteum could be simulated by fat, contrastโ€enhanced blood and artifacts.

Conclusion

The periosteum can be visualized with ultrashort echo time pulse sequences in health and disease. J. Magn. Reson. Imaging 2004;19:99โ€“107. ยฉ 2003 Wileyโ€Liss, Inc.


๐Ÿ“œ SIMILAR VOLUMES


Magnetic resonance imaging with ultrasho
โœ Damian J. Tyler; Matthew D. Robson; R. Mark Henkelman; Ian R. Young; Graeme M. B ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 634 KB

## Abstract It is now possible to detect signals from tissues and tissue components with short T~2~s, such as cortical bone, using ultrashort TE (UTE) pulse sequences. The background to the use of these sequences is reviewed with particular emphasis on MR system issues. Tissue properties are discus

Magnetic resonance imaging of the liver
โœ Karyn E. Chappell; Nayna Patel; Peter D. Gatehouse; Janice Main; Basant K. Puri; ๐Ÿ“‚ Article ๐Ÿ“… 2003 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 263 KB

## Purpose: To assess the feasibility of imaging the liver in volunteers and patients with ultrashort echo time (ute) pulse sequences. ## Materials and methods: Seven normal controls as well as 12 patients with biopsy-proven generalized liver disease and three patients with focal disease were exa

Magnetic resonance imaging of entheses u
โœ Michael Benjamin; Graeme M Bydder ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 626 KB

## Abstract The attachment of tendons, ligaments, and joint capsule to bone (entheses) is reviewed and new options for visualizing key components of entheses provided by ultrashort TE (UTE) pulse sequences are described. Many features of entheses are adapted to the dispersion of stress at the bound

In vivo proton electron double resonance
โœ Ziqi Sun; Haihong Li; Sergey Petryakov; Alex Samouilov; Jay L. Zweier ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 361 KB

## Abstract ## Purpose: To develop and evaluate a twoโ€dimensional (2D) fast spin echo (FSE) pulse sequence for enhancing temporal resolution and reducing tissue heating for in vivo proton electron double resonance imaging (PEDRI) of mice. ## Materials and Methods: A fourโ€compartment phantom cont

Problems with achieving saturation using
โœ I. R. Young; G. M. Bydder; D. J. Bryant ๐Ÿ“‚ Article ๐Ÿ“… 1989 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 303 KB

Attempts at saturation by nonselective rf pulses, followed by gradient spoiler pulses, are sometimes used as the basis of a method of measuring T I in magnetic resonance imaging, because a method of this type is perceived as being less affected by slice shape artifact than partial saturation methods