## Abstract It is now possible to detect signals from tissues and tissue components with short T~2~s, such as cortical bone, using ultrashort TE (UTE) pulse sequences. The background to the use of these sequences is reviewed with particular emphasis on MR system issues. Tissue properties are discus
Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences
β Scribed by Michael Benjamin; Graeme M Bydder
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 626 KB
- Volume
- 25
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
The attachment of tendons, ligaments, and joint capsule to bone (entheses) is reviewed and new options for visualizing key components of entheses provided by ultrashort TE (UTE) pulse sequences are described. Many features of entheses are adapted to the dispersion of stress at the boundary between tendons/ligaments and bone. Of particular interest is fibrocartilage, which has mechanical properties different from those of both βpureβ tendon/ligament and bone. Features typical of entheses can also be seen at sites where tendons or ligaments are in contact with (but not attached to) bone, and the concept of a βfunctional enthesisβ has been developed to emphasize the similarities. The enthesis concept has also been broadened to include the idea of an βenthesis organβ in which many tissues play a role in dissipating stress concentration. UTE pulse sequences can specifically identify the calcified and uncalcified fibrocartilage tissue components of entheses and differentiate these from fibrous connective tissue and bone. These tissues cannot be separately visualized at entheses with conventional pulse sequences. Entheses are involved in overuse syndromes and seronegative spondyloarthropathies (SpA) and there are important issues related to tissue repair and healing following surgery. J. Magn. Reson. Imaging 2007. Β© 2007 WileyβLiss, Inc.
π SIMILAR VOLUMES
## Purpose: To assess the feasibility of imaging the liver in volunteers and patients with ultrashort echo time (ute) pulse sequences. ## Materials and methods: Seven normal controls as well as 12 patients with biopsy-proven generalized liver disease and three patients with focal disease were exa
## Abstract ## Purpose To assess the values of pulse sequences with ultrashort echo times (0.08 msec) for detecting and characterizing periosteum. ## Materials and Methods Two normal volunteers aged 33 and 58 years and 12 patients aged seven to 55 years were studied. A total of 10 of the patient
## Abstract The spatial resolution of magnetic resonance (MR) images is usually specified by using nominal spatial resolution, the width of the simulated pointβspread function (PSF), or measurement from a resolution phantom. The accuracy of these measures is limited because they do not take into ac
## Abstract A technique for producing a quantitative measure of magnetization transfer parameters in a clinically feasible time scale is proposed. The combination of pulsed offβresonance irradiation and echo planar imaging has produced an imaging sequence that negates the need for continuous wave i
Recently, we introduced a new numerical approach to the design and optimization of NMR selective pulses, which we have christened "SPINCALC" (J. T. Ngo and P. G. Morris, Biochem. Soc. Trans. 14, 1271 (1986); J. T. Ngo and P. G. Morris, Magn. Reson. Med. 5, 217 (1987]. The first practical application