𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences

✍ Scribed by Michael Benjamin; Graeme M Bydder


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
626 KB
Volume
25
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The attachment of tendons, ligaments, and joint capsule to bone (entheses) is reviewed and new options for visualizing key components of entheses provided by ultrashort TE (UTE) pulse sequences are described. Many features of entheses are adapted to the dispersion of stress at the boundary between tendons/ligaments and bone. Of particular interest is fibrocartilage, which has mechanical properties different from those of both β€œpure” tendon/ligament and bone. Features typical of entheses can also be seen at sites where tendons or ligaments are in contact with (but not attached to) bone, and the concept of a β€œfunctional enthesis” has been developed to emphasize the similarities. The enthesis concept has also been broadened to include the idea of an β€œenthesis organ” in which many tissues play a role in dissipating stress concentration. UTE pulse sequences can specifically identify the calcified and uncalcified fibrocartilage tissue components of entheses and differentiate these from fibrous connective tissue and bone. These tissues cannot be separately visualized at entheses with conventional pulse sequences. Entheses are involved in overuse syndromes and seronegative spondyloarthropathies (SpA) and there are important issues related to tissue repair and healing following surgery. J. Magn. Reson. Imaging 2007. Β© 2007 Wiley‐Liss, Inc.


πŸ“œ SIMILAR VOLUMES


Magnetic resonance imaging with ultrasho
✍ Damian J. Tyler; Matthew D. Robson; R. Mark Henkelman; Ian R. Young; Graeme M. B πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 634 KB

## Abstract It is now possible to detect signals from tissues and tissue components with short T~2~s, such as cortical bone, using ultrashort TE (UTE) pulse sequences. The background to the use of these sequences is reviewed with particular emphasis on MR system issues. Tissue properties are discus

Magnetic resonance imaging of the liver
✍ Karyn E. Chappell; Nayna Patel; Peter D. Gatehouse; Janice Main; Basant K. Puri; πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 263 KB

## Purpose: To assess the feasibility of imaging the liver in volunteers and patients with ultrashort echo time (ute) pulse sequences. ## Materials and methods: Seven normal controls as well as 12 patients with biopsy-proven generalized liver disease and three patients with focal disease were exa

Magnetic resonance imaging of periosteum
✍ Ines L.H. Reichert; Michael Benjamin; Peter D. Gatehouse; Karyn E. Chappell; Joa πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 506 KB

## Abstract ## Purpose To assess the values of pulse sequences with ultrashort echo times (0.08 msec) for detecting and characterizing periosteum. ## Materials and Methods Two normal volunteers aged 33 and 58 years and 12 patients aged seven to 55 years were studied. A total of 10 of the patient

Estimating the spatial resolution of in
✍ Wen-Tung Wang; Peng Hu; Craig H. Meyer πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 499 KB πŸ‘ 2 views

## Abstract The spatial resolution of magnetic resonance (MR) images is usually specified by using nominal spatial resolution, the width of the simulated point‐spread function (PSF), or measurement from a resolution phantom. The accuracy of these measures is limited because they do not take into ac

Rapid quantitation of magnetization tran
✍ Damian J. Tyler; Penny A. Gowland πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 398 KB

## Abstract A technique for producing a quantitative measure of magnetization transfer parameters in a clinically feasible time scale is proposed. The combination of pulsed off‐resonance irradiation and echo planar imaging has produced an imaging sequence that negates the need for continuous wave i

The design of practical selective pulses
✍ Peter G. Morris; Dominick J. O. McIntyre; David E. Rourke; J. Thomas Ngo πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 461 KB πŸ‘ 1 views

Recently, we introduced a new numerical approach to the design and optimization of NMR selective pulses, which we have christened "SPINCALC" (J. T. Ngo and P. G. Morris, Biochem. Soc. Trans. 14, 1271 (1986); J. T. Ngo and P. G. Morris, Magn. Reson. Med. 5, 217 (1987]. The first practical application