upon the properties of the particular resistors used. It should therefore be used with caution beyond regions where direct calibration is possible. It should also be noted that the Clement and Quinnell empirical resistance-temperature formula 7 approximates equation (1) only for special values of th
Low heat capacity carbon thermometers
โ Scribed by L.P. Mezhov-Deglin; A.I. Shal'nikov
- Publisher
- Elsevier Science
- Year
- 1969
- Tongue
- English
- Weight
- 181 KB
- Volume
- 9
- Category
- Article
- ISSN
- 0011-2275
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
All three solenoids are in a dewar of liquid nitrogen. The helium dewar finger is inside solenoid 3 (the finger is 10 cm long, with inner and outer diameters 3.5 and 5.5 ram) with the specimen mounted at the end of an ivory rod. The end of the rod with the specimen is housed in a thin-walled jacket
The variable-range hopping expression R(T)= Ro e(Tยฐ/rl~ used to describe data for carbon and thick film chip resistors is discussed. For both kinds of resistors it was found that 1/4 \_\_\_(~ \_\_\_ 1/2, although for the thick film resistors the applicability of models originally used in doped semic