## Abstract In vivo longitudinal relaxation times of __N__‐acetyl compounds (NA), choline‐containing substances (Cho), creatine (Cr), __myo__‐inositol (mI), and tissue water were measured at 1.5 and 3 T using a point‐resolved spectroscopy (PRESS) sequence with short echo time (TE). __T__~1~ values
Longitudinal and multi-echo transverse relaxation times of normal breast tissue at 3 Tesla
✍ Scribed by Richard A.E. Edden; Seth A. Smith; Peter B. Barker
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 735 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To measure longitudinal (T~1~) and multi‐echo transverse (T~2~) relaxation times of healthy breast tissue at 3 Tesla (T).
Materials and Methods
High‐resolution relaxation time measurements were made in six healthy female subjects. Inversion recovery images were acquired at 10 inversion times between 100 ms and 4000 ms, and multiple spin echo images were acquired at 16 echo times between 10 ms and 160 ms.
Results
Longitudinal relaxation times T~1~ were measured as 423 ± 12 ms for adipose tissue and 1680 ± 180 ms for fibroglandular tissue. Multi‐echo transverse relaxation times T~2~ were measured as 154 ± 9 ms for adipose tissue and 71 ± 6 ms for fibroglandular tissue. Histograms of the voxel‐wise relaxation times and quantitative relaxation time maps are also presented.
Conclusion
T~1~ and multi‐echo T~2~ relaxation times in normal human breast tissue are reported. These values are useful for pulse sequence design and optimization for 3T breast MRI. Compared with the literature, T~1~ values are significantly longer at 3T, suggesting that longer repetition time and inversion time values should be used for similar image contrast. J. Magn. Reson. Imaging 2010;32:982–987. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To measure ^1^H relaxation times of cerebral metabolites at 3 T and to investigate regional variations within the brain. ## Materials and Methods Investigations were performed on a 3.0‐T clinical whole‐body magnetic resonance (MR) system. T2 relaxation times of N‐acetyl as
## Abstract ## Purpose: To accurately measure T1 and T2 of breast fibroglandular tissue and fat at 1.5T and 3T, and note the partial volume effects of the admixture of fibroglandular tissue and fat on the relaxation rates using an approach termed iterative decomposition of water and fat with echo
## Abstract ## Purpose The purpose of this study is to measure the longitudinal (T1) relaxation time of human lung parenchyma at 3.0 Tesla (T), independent of large vessel signal, and to examine T1 as a function of position in gravitational, isogravitational, and radial planes. ## Materials and M