Liquid chromatography-mass spectrometric method for determination of the non-imidazole H3-receptor antagonist UPR1056 in rat plasma
✍ Scribed by Federica Vacondio; Claudia Silva; Giovanni Morini; Fabrizio Bordi; Lisa Flammini; Elisabetta Barocelli; Marco Mor
- Book ID
- 102443643
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 187 KB
- Volume
- 34
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The non‐imidazole H3 receptor antagonist UPR1056 was dosed in plasma samples from rats individually administered with a single i.p. dose of 1.25 mg/kg by means of a newly validated HPLC‐MS method. UPR1056 was extracted from rat plasma by protein precipitation with acetonitrile and was separated by linear gradient elution, employing water and methanol both additioned with 0.05% trifluoroacetic acid as mobile phases. UPR1056 was detected in MS using an electrospray ion source operating in positive ion mode. Acquisition was performed in single ion monitoring mode at m/z=349.3. The method was validated over the concentration range of 17.43–1743 ng/mL (50–5000 pmol/mL). Within‐ and between‐run precision for the low, mid and high quality controls (QC) levels were 6.75% or less and accuracy ranged from 95.8 to 107.6%. The lower limit of quantification was 17.43 ng/mL. The analysis of the time course of UPR1056 concentrations over the 24‐h period revealed a C~max~ of 1147 ng/mL after 2 h from peripheral administration of the non‐imidazole H~3~‐receptor antagonist, with a prolonged elimination half‐life of over 9 h.