𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Lactate discrimination incorporated into echo-planar spectroscopic imaging

✍ Scribed by Yoshitaka Bito; Toshihiko Ebisu; Satoshi Hirata; Tetsuro Takegami; Yukari Yamamoto; Chuzo Tanaka; Shoji Naruse


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
397 KB
Volume
45
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A technique for discriminating a lactate signal from overlapping lipid signals in ^1^H spectroscopic imaging is presented. It is based on J‐coupling between lactate protons and on the broad spectral bandwidth of lipid signal. Measurement parameters used in the technique are determined so that TE is separated from n/J (n: a natural number, J: J‐coupling constant) enough to suppress the lipid signal at the time when the lactate signal is strongest. Data processing is used to calculate the lactate signal intensity from the reconstructed spectra. This technique enables lactate to be discriminated in a single measurement and enables spectra of other metabolites to be acquired simultaneously. However, it necessitates a homogeneous magnetic field, long TE, and supplementary lipid suppression. Discrimination of the lactate signal is demonstrated by applying lactate‐discriminating echo‐planar spectroscopic imaging (EPSI), which combines this discrimination technique with the standard EPSI, to rat focal cerebral ischemia models. Magn Reson Med 45:568–574, 2001. © 2001 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Volumetric multishot echo-planar spectro
✍ J. Michael Tyszka; Adam N. Mamelak 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 361 KB

## Abstract Rapid volumetric magnetic resonance spectroscopic imaging (MRSI) is potentially of great relevance to the diagnosis and treatment of focal cerebral diseases such as cancer and epilepsy. A strategy for volumetric multishot echo‐planar spectroscopic imaging (MEPSI) is described which allo

In Vivo31P Echo-Planar Spectroscopic Ima
✍ Thomas Wilhelm; Peter Bachert 📂 Article 📅 2001 🏛 Elsevier Science 🌐 English ⚖ 112 KB

Localized phosphorus-31 NMR spectra of human calf muscle in vivo were obtained by means of echo-planar spectroscopic imaging (EPSI) with a 1.5-T whole-body scanner. The technique permits the measurement of two-dimensional 31 P SI data at a minimum acquisition time of 2.4 s (8 × 8 voxels, TR = 300 ms

Design of flyback echo-planar readout gr
✍ Charles H. Cunningham; Daniel B. Vigneron; Albert P. Chen; Duan Xu; Sarah J. Nel 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 223 KB

## Abstract The spatial resolution of conventional magnetic resonance spectroscopic imaging‐(MRSI) is typically coarse, mainly due to SNR limitations. The increased signal available with higher field scanners and new array coils now permits higher spatial resolution, but conventional chemical shift