𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Iterative blind deconvolution in magnetic resonance brain perfusion imaging

✍ Scribed by Renate Grüner; Torfinn Taxt


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
791 KB
Volume
55
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

In first pass magnetic resonance brain perfusion imaging, arterial input functions are used in the deconvolution of the observed contrast concentrations to obtain quantitative hemodynamic parameters. Ideally, arterial input functions should be measured in each imaged voxel to eliminate the effects of delay and dispersion of the contrast agent from the injection site. An approach based on iterative blind deconvolution with the Richardson–Lucy algorithm is proposed for the simultaneous estimation of voxel‐specific arterial input functions and voxel‐specific tissue residue functions. An extended contrast concentration model was used to separate the first pass bolus from additional recirculation and leakage signals. The extended model was evaluated using in vivo data. Computer simulations examined the feasibility of iterative blind deconvolution in perfusion imaging. Preliminary in vivo results from a patient with fibromuscular dysplasia showed territories with delayed/dispersed arterial input functions that coincided with the location of territories supplied by collateral circulation as described from the complete radiologic examination. Higher flow values and shorter mean transit times compared to conventional methods were obtained in these areas, suggesting that the effects of dispersion were minimized. The in vivo estimated arterial input functions visualized the patient's blood supply patterns as a function of time. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Brain perfusion imaging using magnetic r
✍ C. Leon Partain 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 29 KB 👁 1 views

Next, the manuscripts underwent review by the editorial board of JMRI. This scientific symposium was designed to describe and review current methods of quantitative cerebral perfusion imaging in the human brain using MRI, to evaluate different methods, to describe new developments, and to assess cl

Magnetic resonance brain perfusion imagi
✍ Renate Grüner; Bård T. Bjørnarå; Gunnar Moen; Torfinn Taxt 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 851 KB

## Abstract ## Purpose To propose an automatic method for estimating voxel‐specific arterial input functions (AIFs) in dynamic contrast brain perfusion imaging. ## Materials and Methods Voxel‐specific AIFs were estimated blindly using the theory of homomorphic transformations and complex cepstru

Spectroscopic and perfusion magnetic res
✍ A. Aria Tzika; Loukas G. Astrakas; Maria K. Zarifi; David Zurakowski; Tina Young 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 718 KB

## Abstract ## BACKGROUND In vivo biomarkers to predict progression of brain tumors are of great value in clinical practice. Therefore, the authors tested the hypothesis that changes in choline ratios by magnetic resonance (MR) spectroscopic imaging and/or relative tumor blood volume (rTBV) can di

Automatic quality assessment in structur
✍ Bénédicte Mortamet; Matt A. Bernstein; Clifford R. Jack Jr.; Jeffrey L. Gunter; 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 434 KB 👁 1 views

## Abstract MRI has evolved into an important diagnostic technique in medical imaging. However, reliability of the derived diagnosis can be degraded by artifacts, which challenge both radiologists and automatic computer‐aided diagnosis. This work proposes a fully‐automatic method for measuring imag