Investigation of the imaging characteristics of the Gd2O3:Eu nanophosphor for high-resolution digital X-ray imaging system
β Scribed by So-yeong Kim; Ji-koon Park; Sang-sik Kang; Byung-youl Cha; Sung-ho Cho; Jung-wook Shin; Dae-woong Son; Sang-hee Nam
- Publisher
- Elsevier Science
- Year
- 2007
- Tongue
- English
- Weight
- 668 KB
- Volume
- 576
- Category
- Article
- ISSN
- 0168-9002
No coin nor oath required. For personal study only.
β¦ Synopsis
For possible applications in high-resolution medical image systems, we manufactured a Eu 3+ -doped Gd 2 O 3 nanophosphor using the low-temperature solution combustion method, and evaluated its performance as an image sensor. The structural and optical characteristics of the fabricated nanophosphor were investigated using field-emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), photoluminescence spectrum (PL), and luminescence decay time measurements. From the FE-SEM and XRD results, we established that the fabricated nanophosphor was formed of spherical particles of about 30-40 nm, and confirmed that the particles agglomerated as the sintering temperature increases. From PL spectra, a strong peak appeared near 611 nm, and the luminescent intensity was seen to be affected by the doping concentration of Eu. Gd 2 O 3 :Eu nanophosphor particles have shown the highest luminescent efficiency at a Eu concentration of 5 wt%. In the luminescent decay time measurements, the mean decay time was about 2.3-2.6 ms, about two times longer than that of the general bulk phosphor, and affected by the of Eu-doping concentration. For the investigation of the imaging characteristics of the fabricated nanophosphor, we connected the Gd 2 O 3 :Eu nanophosphor film to a commercial CMOS image sensor, obtained the X-ray images and evaluated the modulation transfer function (MTF) as a function of the Eu concentration. We were able to obtain high-resolution X-ray images and found that the Eu concentration also influenced the imaging characteristics.
π SIMILAR VOLUMES
A software and some useful tools have been developed for identifying individual x-ray reflectional peaks recorded with an x-ray imaging plate system. These techniques were applied to analyze the crystal structure of uniaxially oriented polymer samples. Characteristic features of the present method m
## Abstract An Xβray imaging plate system has been applied for the first time to evaluate the crystallite modulus __E__~c~ of orthorhombic polyethylene along the chain axis. The __E__~c~ evaluated by using the 002 reflection was 234.9 Β± 12.6 GPa and that for the 004 reflection was 236.7 Β± 3.4 GPa.