Integrated thermal simulation of buildings and regenerative evaporative coolers
โ Scribed by P.G. Rousseau; E.H. Mathews; L.J. Grobler
- Publisher
- Elsevier Science
- Year
- 1994
- Tongue
- English
- Weight
- 805 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0360-1323
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
A mathematical model has been developed to evaluate the relative thermal performance of a building coupled with an indirect or direct evaporative cooler. Using periodic analysis for taking into account thermal storage of building envelope, explicit expressions have been obtained for room air tempera
The thermal performance of a non-conditioned building fitted with an indirect evaporative cooler (IEC) has been investigated in terms of hourly, monthly and seasonal discomfort index. The effect of various design parameters of the IEC on the discomfort index has been investigated for three different