𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Influence of hydroxyapatite microstructure on human bone cell response

✍ Scribed by Myriam Rouahi; Olivier Gallet; Eric Champion; Joseph Dentzer; Pierre Hardouin; Karine Anselme


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
691 KB
Volume
78A
Category
Article
ISSN
1549-3296

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Microstructure of calcium phosphate ceramics has been shown to influence long‐term in vitro cellular events like proliferation and differentiation, and to favor bone integration in vivo. As long‐term cellular events are known to be dependent of early cell adhesion events, we decided to study the in vitro influence of the microstructure of a microporous hydroxyapatite (mHA) and a nonmicroporous hydroxyapatite (pHA) ceramic on serum protein adsorption and SaOs‐2 human bone cells attachment after 30 min, 1, 4, and 24 h and cell growth after 96 h. Plastic coverslips were used as controls. Hydroxyapatite composition of mHA and pHA was confirmed by X‐ray diffraction and Fourier transform infra‐red spectroscopy. The surface energies of ceramics were calculated from contact‐angle measurements in di‐iodomethane, water or complete culture medium. The total surface energy was 44.8 mJ/m^2^ for pHA and 48.7 mJ/m^2^ for plastic. The contact‐angle measurement was impossible on mHA likely because they displayed 12% of open microporosity, pHA ceramic exhibiting only closed pores (2.5%). Moreover, the roughness amplitude was largely higher on mHA (Sa = 4.35 μm) than on pHA (Sa = 0.065 μm) and plastic (Sa = 0.042 μm). Three different techniques were used to evaluate protein adsorption on the ceramics. SDS‐PAGE of desorbed proteins demonstrated that more proteins desorbed from mHA (66.02 μg/m^2^) than from pHA (17.2 μg/m^2^) or plastic (0.08 μg/m^2^). A new method was used to evaluate in situ the quantity of adsorbed total proteins: the temperature‐programmed desorption (TPD) analysis coupled with mass spectrometry. The TPD analysis confirmed that 10‐fold more proteins adsorbed on mHA compared with those on pHA. A direct immunolabeling on ceramics revealed than more fibronectin and serum albumin adsorbed on microporous ceramic than on dense ceramic. The morphology of SaOs‐2 cells was the same on all the substrates after 30 min. At later time points, cell morphology on mHA was radically different than on other surfaces, with the particularity of the cytoplasmic edge that appeared undistinguishable from the surface. Only the extremity of the cells and lamellipodia were visible. Cells seemed like “adsorbed” by the mHA surface, whereas on plastic and pHA surfaces the cells displayed classical aspects of polygonal spreading. The cells displayed on mHA the highest initial attachment potential after 30 min, 1, 4, 24 h but the lower proliferation potential after four days. This study confirms that a microporous ceramic surface can modulate the adsorption of proteins and further the adhesion and proliferation of human bone cells. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006


📜 SIMILAR VOLUMES


Influence of hydroxyapatite particle siz
✍ Sun, Jui-Sheng ;Liu, Hwa-Chang ;Hong-Shong Chang, Walter ;Li, Jimmy ;Lin, Feng-H 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 77 KB 👁 1 views

Over the past decade, a large number of biomaterials have been proposed as artificial bone fillers for repairing bone defects. The material most widely used in clinical medicine is hydroxyapatite. The aim of our investigation was to study the effect of hydroxyapatite size mechanism on osteoblasts.

Polarization of hydroxyapatite: Influenc
✍ D. Kumar; J.P. Gittings; I.G. Turner; C.R. Bowen; A. Bastida-Hidalgo; S.H. Cartm 📂 Article 📅 2010 🏛 Elsevier Science 🌐 English ⚖ 367 KB

Hydroxyapatite (HA) has been used clinically to treat bone defects. However, modifications of the surface properties of HA could improve and control bone matrix deposition and localized host tissue integration. The aim of this study was to investigate the effect of developing a surface charge on HA

The influence of hydroxyapatite particle
✍ Sun, Jui-Sheng ;Lin, Feng-Huei ;Hung, Tsai-Yi ;Tsuang, Yang-Hwei ;Chang, Walter 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 605 KB

Aseptic loosening after total joint arthroplasty is a major problem in orthopedic surgery. Small particles from material wear have been reported as the main cause of implant failure. For this reason, investigation into possible wear particles from the materials used in the implant may lead to longev

The influence of calcium phosphate bioma
✍ Grégoire, M. ;Orly, I. ;Menanteau, J. 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 982 KB

An in vitro method is described to assess the influence of synthetic calcium phosphate powders on osteoblast activities. Human osteoblast cell cultures were established from iliac crest. MC3T3-El, an established osteogenic cell line, was employed as a control. Scanning and transmission electron micr