𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Influence of fan setting height on the cooling performance of a plate-fin-type heat sink with microprocessor

✍ Scribed by Keizou Kawamura; Tadakatsu Nakajima; Hitoshi Matsushima


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
147 KB
Volume
30
Category
Article
ISSN
1099-2871

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The cooling performance of a plate‐fin‐type heat sink equipped with a cooling fan was investigated experimentally. The heat sink was 80 mm long, 43 mm wide, and 24 mm in height (including the 4‐mm‐thick base). The cooling fan was 40 × 40 × 15 mm and was set to direct the air flow vertically in the downstream half of the heat sink. We focused on the influence of the height (which varied from 5 to 20 mm) that the fan was set at, on the heat transfer coefficient of the heat sink. The maximum value of the heat transfer coefficient was achieved at a setting height of 5 mm. At this height, the volumetric heat transfer coefficient was 1.8 times as high as that in a parallel flow under the same fan power. This result indicates that the cooling performance of heat sinks with a cooling fan can be improved by using this kind of compact structure. © 2001 Scripta Technica, Heat Trans Asian Res, 30(6): 512–520, 2001


📜 SIMILAR VOLUMES


The influence of a plate-type heat sink
✍ Junpei Nonaka; Shuichi Nitta; Atsuo Mutoh 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 185 KB

Increases in the power density per unit volume of an IC due to higher density of integration and higher operating speed cause increased heat generation. In order to avoid undesirable effects of the temperature increase on the reliability of the devices, heat sinks are installed. However, although mu