Indirect Spectrofluorimetric Determination of Piroxicam and Propranolol Hydrochloride in Bulk and Pharmaceutical Preparations
β Scribed by K. C. Ramesh; B. G. Gowda; J. Seetharamappa; J. Keshavayya
- Book ID
- 111558100
- Publisher
- SP MAIK Nauka/Interperiodica
- Year
- 2003
- Tongue
- English
- Weight
- 29 KB
- Volume
- 58
- Category
- Article
- ISSN
- 1061-9348
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
Recovery experiment. To determine the precision and accuracy of the above method, recovery experiments were performed using the method of additions. A fixed volume sample of solution was added to one of three different concentrations of the standard drug solution. The results are shown in Table 2.
A rapid and highly sensitive fluorimetric procedure was developed for the routine determination of reserpine in bulk, in dosage forms and in biological fluids. The method is based on the fluorescence induced by oxidation of reserpine with 2-iodoxybenzoate in aqueous acetic acid. The oxidation produc