In vivo MR elastography of the prostate gland using a transurethral actuator
✍ Scribed by Rajiv Chopra; Arvin Arani; Yuexi Huang; Mireía Musquera; Jeff Wachsmuth; Michael Bronskill; Donald Plewes
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 524 KB
- Volume
- 62
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Conventional approaches for MR elastography (MRE) using surface drivers have difficulty achieving sufficient shear wave propagation in the prostate gland due to attenuation. In this study we evaluate the feasibility of generating shear wave propagation in the prostate gland using a transurethral device. A novel transurethral actuator design is proposed, and the performance of this device was evaluated in gelatin phantoms and in a canine prostate gland. All MRI was performed on a 1.5T MR imager using a conventional gradient‐echo MRE sequence. A piezoceramic actuator was used to vibrate the transurethral device along its length. Shear wave propagation was measured transverse and parallel to the rod at frequencies between 100 and 250 Hz in phantoms and in the prostate gland. The shear wave propagation was cylindrical, and uniform along the entire length of the rod in the gel experiments. The feasibility of transurethral MRE was demonstrated in vivo in a canine model, and shear wave propagation was observed in the prostate gland as well as along the rod. These experiments demonstrate the technical feasibility of transurethral MRE in vivo. Further development of this technique is warranted. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Proton magnetic resonance spectroscopic imaging (^1^H‐MRSI) has been advocated as a valuable tool for prostate cancer diagnosis. However, a barrier to widespread clinical use of this technique is the lack of robust quantification methods that yield reproducible results in an institution
## Abstract __In vivo__ ^1^H MR spectra of the prefrontal cortex acquired with the stimulated echo acquisition mode (STEAM) __TE__ = 20 ms sequence were quantified to determine relative levels of cerebral metabolites. __A priori__ knowledge of spectra from individual metabolites in aqueous solution
## Abstract ## Purpose To investigate the feasibility of obtaining high‐resolution MR images for the detection of pathological changes occurring in the injured rat spinal cord with a routine clinical 3.0T imaging system. ## Materials and Methods Adult female Fischer 344 rats received thoracic sp