## Abstract Primary cementless joint replacement depends partly on the ability of bone to heal into those areas of an inserted implant where a gap to surrounding bone initially exists. A new bone preparation technique, compaction, has enhanced gap‐healing around grit‐blasted implants without osteoc
In vivo effects of RGD-coated titanium implants inserted in two bone-gap models
✍ Scribed by Brian Elmengaard; Joan E. Bechtold; Kjeld Søballe
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 246 KB
- Volume
- 75A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
RGD (Arg‐Gly‐Asp) coating has been suggested to enhance implant fixation by facilitating the adhesion of osteogenic cells to implant surfaces. Orthopedic implants are unavoidably surrounded partly by gaps, and these regions represent a challenging environment for osseointegration. We examined the effects of cyclic RGD‐coated implants on tissue integration and implant fixation in two cancellous bone‐gap models. In canines, we inserted loaded RGD‐coated implants with 0.75‐mm gap (n = 8) and unloaded RGD‐coated implants with 1.5‐mm gap (n = 8) into the distal femur and proximal tibia, respectively. Control gap implants without RGD were inserted contralaterally. The titanium alloy (Ti‐6Al‐4V) implants were plasma sprayed and cylindrical. The observation period was 4 weeks and the fixation was evaluated by push‐out test and histomorphometry. Mechanical implant fixation was improved for RGD‐coated implants. Unloaded RGD‐coated implants showed a significant increase in bone whereas both loaded and unloaded implants showed a significant reduction in fibrous tissue anchorage. The results are encouraging, because RGD had an overall positive effect on the fixation of titanium implants in regions where gaps exist with the surrounding bone. RGD peptide coatings can potentially be used to enhance tissue integration in these challenging environments. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
📜 SIMILAR VOLUMES
This study was undertaken to evaluate the effect of coating characteristics on the mechanical strengths of the plasma-sprayed HA-coated Ti-6Al-4V implant system both in vitro and in vivo. Two types of HA coatings (HACs) with quite different microstructures, concentrations of impurityphases, and indi
## Abstract Previously, we reported that application of 10 μg recombinant human TGF‐β2 (rhTGF‐β2) enhanced peri‐implant bone formation and bone‐implant contact in a rat model. To further investigate the dose effect, the present experiment evaluated doses of rhTGF‐β2 bracketed around 10 μg (5, 10, 2