✦ Synopsis


In vivo measurement of T2 relaxation times in multiple sclerosis (MS) lesions by magnetic resonance imaging (MRI) is potentially useful for the evaluation of the disease activity. Seven patients with definite MS were investigated over a period of three years (19 examinations), using a whole-body MRI scanner operating at 0.15 T with a specially designed high-power radio-frequency head coil. A modified CPMG sequence with a 180 degree pulse interval of TE = 6 msec and 128 echoes was used for the T2 relaxation measurement of the areas of increased signal (AIS) and white matter (WM). A biexponential T2 analysis of each pixel of the spin-echo images was computed. The T2 relaxation processes were found to be a monoexponential function in WM. The T2 relaxation times of apparently normal white matter in MS patients was significantly longer than in control subjects. The T2 relaxation curves of the AIS were found in most cases to fit a biexponential function characterized by a short and a long T2. T2 long relaxation times of AIS were spread out over a wide range (150-560 msec). The study of T2 long histograms shows that some AIS can be divided into two or three parts depending on the T2 long values. Each of these parts may correspond to a pathological process such as edema, demyelination and gliosis. Evolution of T2 relaxation times over a period of time cannot as yet be correlated with modifications in the clinical state.


πŸ“œ SIMILAR VOLUMES


In vivo determination of T1 and T2 in th
✍ H. B. W. Larsson; J. Frederiksen; L. KjΓ¦r; O. Henriksen; J. Olesen πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 600 KB

In vivo measurements of relaxation processes in multiple sclerosis (MS) lesions by magnetic resonance imaging (MRI) may be important for evaluation of the disease activity in individual MS plaques. To obtain information of presumably chronic plaques, 10 patients with severe, but stable MS were inves

In vivo evaluation of the reproducibilit
✍ H.B.W. Larsson; P. Christiansen; I. Zeeberg; O. Henriksen πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 661 KB

The precision (reproducibility) of relaxation times derived from magnetic resonance images of patients with multiple sclerosis (MS) were investigated. Measurements of 10 MS patients were performed at 1.5 T on two occasions within 1 wk. T1 and T2 was measured using a partial saturation inversion reco

Localized in vivo proton spectroscopy in
✍ H. B. W. Larsson; P. Christiansen; M. Jensen; J. Frederiksen; A. Heltberg; J. Ol πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 538 KB

## Abstract Localized proton spectroscopy was performed in 15 patients with acute or chronic multiple sclerosis (MS). Some of the patients were investigated serially, being given a total of 22 spectroscopic investigations. Resonances corresponding to free lipids were observed in six plaques. This w

In vivo magnetic resonance diffusion mea
✍ H.B.W. Larsson; C. Thomsen; J. Frederiksen; M. Stubgaard; O. Henriksen πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 899 KB

Measurement of water self-diffusion in the brain in 25 patients with multiple sclerosis was performed by magnetic resonance imaging. Quantitative diffusion measurements were obtained using single spin-echo pulse sequences with pulsed magnetic field gradients of different magnitude. Twenty-two of the

An in vivo NMR imaging determination of
✍ Sumie Shioya; Rebecca Christman; David C. Ailion πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 484 KB

## Abstract We describe the first __in vivo__ imaging determination of normal lung tissue's multiexponential transverse magnetization decay. Normal spontaneously breathing rats were used for the measurements. To obtain motion‐insensitive images, we used a modified line scan imaging technique which