𝔖 Bobbio Scriptorium
✦   LIBER   ✦

In-source fragmentation of partially oxidized mono- and polycyclic aromatic hydrocarbons in atmospheric pressure chemical ionization mass spectrometry coupled to liquid chromatography

✍ Scribed by T. Letzel; U. Pöschl; E. Rosenberg; M. Grasserbauer; R. Niessner


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
245 KB
Volume
13
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


Partially oxidized derivatives of polycyclic aromatic hydrocarbons (PAHs) are known to be important environmental pollutants. For the identification of these substances in complex mixtures, e.g. atmospheric aerosol samples, liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization (LC/APCI-MS) has been found to be a suitable analytical technique. In this study 31 derivatives of monoand polycyclic aromatic hydrocarbons with up to five condensed aromatic rings carrying different functional groups (carboxyl, dicarboxylic anhydride, lactone, hydroxyl, and carbonyl) were characterized by LC/APCI-MS. Each substance was measured in positive and negative ion detection mode at four different fragmentor voltages (90 to 190 V). For the first time, the results show that characteristic and wellinterpretable fragmentation patterns can be obtained for these classes of compounds by in-source collisioninduced dissociation in a single quadrupole LC/APCI-MS system. For each class of compounds typical spectral features and optimum measurement conditions are reported, and fragmentation pathways are proposed. The study demonstrates the applicability of LC/APCI-MS for the determination of most of the investigated compounds at trace levels, and it provides a database for the identification of unknown partially oxidized aromatic hydrocarbons.


📜 SIMILAR VOLUMES


Determination of 21-hydroxydeflazacort i
✍ Ifa, Demian R.; Moraes, Maria E.; Moraes, Manuel O.; Santagada, Vincenzo; Calien 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 85 KB 👁 2 views

A liquid chromatographic atmospheric pressure chemical ionization tandem mass spectrometric method is described for the determination of 21-hydroxydeflazacort in human plasma using dexamethasone 21-acetate as an internal standard. The procedure requires a single diethyl ether extraction. After evapo

Validation of higher-throughput high-per
✍ Inhou Chu; Leonard Favreau; Tony Soares; Chin-chung Lin; Amin A. Nomeir 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 166 KB 👁 2 views

In the early stage of drug discovery, thousands of new chemical entities (NCEs) may be screened before a single drug candidate can be identified for development. In order to accelerate the drug discovery process, we have developed higher-throughput enzyme assays to evaluate the inhibition of cytochr