In Situ Monitoring with Impedance Spectroscopy creases only in the terminal stage of the test, indicating the beginning of the tertiary stage more precisely than the creep curve. Thus, the beginning of the tertiary stage may be characterized by increasing amount of damage processes. Figure shows t
In-situ monitoring of the efficiency of the cathodic protection of reinforced concrete by electrochemical impedance spectroscopy
β Scribed by F. Pruckner; J. Theiner; J. Eri; G.E. Nauer
- Publisher
- Elsevier Science
- Year
- 1996
- Tongue
- English
- Weight
- 554 KB
- Volume
- 41
- Category
- Article
- ISSN
- 0013-4686
No coin nor oath required. For personal study only.
β¦ Synopsis
In the course of applying cathodic protection on concrete structures exposed to chloride contamination (sea-water or de-icing salt), characterization of the effectiveness of the protection procedure is a most important point. This effectiveness is related with the removal of aggressive ions and with the rebuilding of the passive layer on the steel surface. The measuring-procedure applied until now is based on the measurement of the change with time of the potential difference between the reinforcement and (normally embedded) reference electrodes after switching off the protection current. The criterion defined by NACE (National Association of Corrosion Engineers) for a sufficient working of a cathodic protection installation is based on empirically evaluated values. The workability of an improved cathodic protection equipment, using recently developed anodic materials[l], was monitored by impedance spectroscopic techniques. A strong dependence of the charge transfer resistance (R,J values of the corrosion reaction on the cathodic charge consumed during the protection procedure was found. Results from linear polarization and corrosion potential measurements are well comparable with the impedance data. The main advantage of the impedance technique is the capability of a fast and automatic measuring procedure and of the possibility of on-line monitoring.
π SIMILAR VOLUMES
## Abstract Although rarely considered, especially within the investigation of steel corrosion phenomena or electrochemical protection techniques in reinforced concrete structures, the concrete bulk matrix has a significant contribution in the global performance of the system βreinforced concrete.β
In situ Monitoring of Electrochemical Processes at the (100) p-Si/ Aqueous NH4F Electrolyte Interface by Photoluminescence. -The influence of the etch rate of oxidized Si atoms in F-solutions on the concentration of nonradiative recombination centers at the Si surface during electropolishing and hy