## Abstract This work describes an auto‐calibrated method for parallel imaging with spiral trajectory. The method is a __k__‐space approach where an interpolation kernel, accounting for coil sensitivity factors, is derived from experimental data and used to interpolate the reduced data set in paral
Improved self-calibrated spiral parallel imaging using JSENSE
✍ Scribed by Jinhua Sheng; Erik Wiener; Bo Liu; Fernando Boada; Leslie Ying
- Publisher
- Elsevier Science
- Year
- 2009
- Tongue
- English
- Weight
- 755 KB
- Volume
- 31
- Category
- Article
- ISSN
- 1350-4533
No coin nor oath required. For personal study only.
✦ Synopsis
Spiral MRI has several advantages over Cartesian MRI such as faster acquisitions and reduced demand in gradient. In parallel imaging, spiral trajectories are especially of great interest due to their inherent self-calibration capabilities, which is especially useful for dynamic imaging applications such as fMRI and cardiac imaging. The existing self-calibration techniques use the central spiral data that are sampled densely in the accelerated acquisition for coil sensitivity estimation. However, the resulting sensitivities are not sufficiently accurate for SENSE reconstruction due to the data truncation. In this paper, JSENSE which has been successfully used in Cartesian trajectories is extended to spiral trajectory such that the coil sensitivities and the desired image are reconstructed jointly to improve accuracy through alternating optimization. The improved sensitivities lead to a more accurate SENSE reconstruction. The results from both phantom and in vivo data are shown to demonstrate the effectiveness of JSENSE for spiral trajectory.
📜 SIMILAR VOLUMES
## Abstract Spiral chemical shift imaging (CSI) is a fast CSI technique that simultaneously encodes 1D spectral and 2D spatial information. Therefore, it potentially allows one to perform a 2D‐CSI experiment in a single shot. However, for most applications, limitations on maximum gradient strength
## Abstract Split‐blade diffusion‐weighted periodically rotated overlapping parallel lines with enhanced reconstruction (DW‐PROPELLER) was proposed to address the issues associated with diffusion‐weighted echo planar imaging such as geometric distortion and difficulty in high‐resolution imaging. Th
Self-imaging theory is widely accepted as a good method in designing 1 Â N multimode interference (MMI) couplers, but it is also true that self-imaging theory is not suitable for low-contrast structures. An improved self-imaging theory is proposed in this paper for the optimal design of low-contrast
## Abstract In this paper, we describe a method for detecting and correcting in‐plane bulk translational motion in multislice spin‐echo imaging using self‐calibration and postprocessing. A constant phase encoding offset between slices is used to evenly spread out the low spatial frequency echoes to