𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fast parallel spiral chemical shift imaging at 3T using iterative SENSE reconstruction

✍ Scribed by Dirk Mayer; Dong-Hyun Kim; Daniel M. Spielman; Roland Bammer


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
586 KB
Volume
59
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Spiral chemical shift imaging (CSI) is a fast CSI technique that simultaneously encodes 1D spectral and 2D spatial information. Therefore, it potentially allows one to perform a 2D‐CSI experiment in a single shot. However, for most applications, limitations on maximum gradient strength and slew rate make multiple excitations necessary in order to achieve a desired spectral bandwidth. In this work we reduce the number of spatial interleaves and, hence, the minimum total measurement time of spiral CSI by using an iterative sensitivity encoding reconstruction algorithm which utilizes complementary spatial encoding afforded by the spatially inhomogeneous sensitivity profiles of individual receiver coils. The performance of the new method was evaluated in phantom and in vivo experiments. Parallel spiral CSI produced maps of brain metabolites similar to those obtained using conventional gridding reconstruction of the fully sampled data with only a small decrease in time‐normalized signal‐to‐noise ratio and a small increase in noise for higher acceleration factors. Magn Reson Med 59:891–897, 2008. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Fast CT-PRESS-based spiral chemical shif
✍ Dirk Mayer; Dong-Hyun Kim; Elfar Adalsteinsson; Daniel M. Spielman 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 293 KB

## Abstract A new sequence is presented that combines constant‐time point‐resolved spectroscopy (CT‐PRESS) with fast spiral chemical shift imaging. It allows the acquisition of multivoxel spectra without line splitting with a minimum total measurement time of less than 5 min for a field of view of

Optimization of fast spiral chemical shi
✍ Y.S. Levin; D. Mayer; Y.-F. Yen; R.E. Hurd; D.M. Spielman 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 566 KB

## Abstract A least‐squares–based optimization and reconstruction algorithm has been developed for rapid metabolic imaging in the context of hyperpolarized ^13^C. The algorithm uses a priori knowledge of resonance frequencies, J‐coupling constants, and __T__~2~\* values to enable acquisition of hig

Comparison of spiral imaging and SENSE-E
✍ Jeff D. Winter; Julien Poublanc; Adrian P. Crawley; Andrea Kassner 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 639 KB

## Abstract ## Purpose To quantitatively compare spiral imaging and sensitivity‐encoded‐echo‐planar‐imaging (SENSE‐EPI) methods for blood oxygen level‐dependent (BOLD) imaging using controlled changes in the end‐tidal partial pressure of CO~2~ (PetCO~2~) to provide a global BOLD response. Specific

Feasibility of dynamic susceptibility co
✍ Janine M. Lupo; Michael C. Lee; Eric T. Han; Soonmee Cha; Susan M. Chang; Mitche 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 559 KB

## Abstract ## Purpose To investigate changes in image and dynamic signal‐to‐noise ratios (SNRs) of the ΔR2\* curve, as well as magnetic susceptibility‐induced artifacts between a standard quadrature head coil and an eight‐channel phased‐array coil with and without sensitivity‐encoding (SENSE) at

MRI of the neck at 3 Tesla using the per
✍ Yoshimitsu Ohgiya; Jumpei Suyama; Noritaka Seino; Shu Takaya; Masaaki Kawahara; 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 278 KB 👁 2 views

## Abstract ## Purpose: To evaluate motion artifacts, tissue contrasts, and lesion detectability in the neck with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) technique. ## Materials and Methods: A total of 46 patients referred for MRI of t