✦ Synopsis


Abstract

Purpose:

To investigate arterial spin labeling (ASL) methods for improved brain perfusion mapping. Previously, pseudo‐continuous ASL (pCASL) was developed to overcome limitations inherent with conventional continuous ASL (CASL), but the control scan (null pulse) in the original method for pCASL perturbs the equilibrium magnetization, diminishing the ASL signal. Here, a new modification of pCASL, termed mpCASL is reported, in which the perturbation caused by the null pulse is reduced and perfusion mapping improved.

Materials and Methods:

improvements with mpCASL are demonstrated using numerical simulations and experiments. ASL signal intensity as well as contrast and reproducibility of in vivo brain perfusion images were measured in four volunteers who had MRI scans at 4 Tesla and the data compared across the labeling methods.

Results:

Perfusion maps with mpCASL showed, on average, higher ASL signal intensity and higher image contrast than those from CASL or pCASL. Furthermore, mpCASL yielded better reproducibility in repeat scans than the other methods.

Conclusion:

The experimental results are consistent with the hypothesis that the new null pulse of mpCASL leads to improved brain perfusion images. J. Magn. Reson. Imaging 2010;31:1419–1427. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Implementation of quantitative perfusion
✍ Eric C. Wong; Richard B. Buxton; Lawrence R. Frank 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 626 KB

We describe here experimental considerations in the implementation of quantitative perfusion imaging techniques for functional MRI using pulsed arterial spin labeling. Three tagging techniques: EPISTAR, PICORE, and FAIR are found to give very similar perfusion results despite large differences in st

3D GRASE PROPELLER: Improved image acqui
✍ Huan Tan; W. Scott Hoge; Craig A. Hamilton; Matthias Günther; Robert A. Kraft 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 370 KB

## Abstract Arterial spin labeling is a noninvasive technique that can quantitatively measure cerebral blood flow. While traditionally arterial spin labeling employs 2D echo planar imaging or spiral acquisition trajectories, single‐shot 3D gradient echo and spin echo (GRASE) is gaining popularity i

Pseudo-continuous arterial spin labeling
✍ Afonso C. Silva; Seong-Gi Kim 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 76 KB

Cerebral blood flow (CBF) can be measured noninvasively with nuclear magnetic resonance (NMR) by using arterial water as an endogenous perfusion tracer. However, the arterial spin labeling (ASL) techniques suffer from poor temporal resolution due to the need to wait for the exchange of labeled arter

Fast, pseudo-continuous arterial spin la
✍ Luis Hernandez-Garcia; Gregory R. Lee; Alberto L. Vazquez; Douglas C. Noll 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 466 KB

## Abstract A fast, two‐coil, pseudo‐continuous labeling scheme is presented. This new scheme permits the collection of a multislice subtraction pair in <3 s, depending on the subject's arterial transit times. The method consists of acquiring both control and tag images immediately after a labeling

Improving the amplitude-modulated contro
✍ Richard Werner; David G. Norris; Karsten Alfke; H. Maximilian Mehdorn; Olav Jans 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 477 KB

## Abstract The use of an amplitude‐modulated radiofrequency (RF) pulse for a control experiment is a proven method to control for off‐resonance effects in multislice continuous arterial spin labeling (CASL) experiments. This method is also known as double adiabatic inversion. The adiabaticity fact

Improved accuracy of human cerebral bloo
✍ Laura M. Parkes; Paul S. Tofts 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 291 KB

A two-compartment exchange model for perfusion quantification using arterial spin labeling (ASL) is presented, which corrects for the assumption that the capillary wall has infinite permeability to water. The model incorporates an extravascular and a blood compartment with the permeability surface a