𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Improved cerebrospinal fluid flow measurements using phase contrast balanced steady-state free precession

✍ Scribed by Erin J. McCormack; Michael R. Egnor; Mark E. Wagshul


Book ID
103840321
Publisher
Elsevier Science
Year
2007
Tongue
English
Weight
741 KB
Volume
25
Category
Article
ISSN
0730-725X

No coin nor oath required. For personal study only.

✦ Synopsis


We present a demonstration of phase contrast balanced steady-state free precession (PC-bSSFP) for measuring cerebrospinal fluid (CSF) flow in the brain and spine, and a comparison of measurements obtained with this technique to conventional phase contrast using incoherent gradient echoes (PC-GRE). With PC-GRE sequences, CSF images suffer from low signal-to-noise ratio (SNR), due to short repetition times required for adequate temporal resolution, and the long relaxation time of CSF. Furthermore, CSF flow is often nonlaminar, causing phase dispersion and signal loss in PC-GRE images. It is hypothesized that PC-bSSFP can improve CSF flow measurements with its high SNR and insensitivity to turbulent flow effects. CSF images acquired from the two techniques were compared in 13 healthy volunteers. Three measures were used to objectively evaluate the PC-bSSFP sequence: the CSF flow percentage, defined as the percentage of the total CSF region exhibiting pulsatile flow, net stroke volume and SNR. Images acquired with PC-bSSFP demonstrated pulsatile CSF flow in 35.8% (P<.005), 11.2% (P<.05) and 27.8% (P<.0005) more pixels than PC-GRE in the prepontine cistern, anterior and posterior cervical subarachnoid space (SAS), respectively. Likewise, measurements of stroke volume in these regions increased by 61.6% (P<.05), 16.8% (P<.001) and 48.3% (P<.0001), respectively. Similar comparisons in the aqueduct showed no statistical difference in stroke volumes between the two techniques (P=.5). The average gain in SNR was 3.3+/-1.7 (P<.001) in the prepontine cistern, 5.0+/-0.2 (P<.01) at the cervical level and 2.0+/-0.4 (P<.001) in the aqueduct in PC-bSSFP magnitude images over PC-GRE images. In addition to the obvious advantage of increased SNR, these results indicate that PC-bSSFP provides more complete measurements of CSF flow data than PC-GRE. PC-bSSFP can be used as a reliable technique for CSF flow quantification for the characterization of normal and altered intracranial CSF flow patterns.


📜 SIMILAR VOLUMES


Phase contrast using multiecho steady-st
✍ Vinay M. Pai 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 745 KB

## Abstract Conventional phase‐contrast (PC) MRI is limited in the temporal resolution (typically 50 ms) that can be achieved, due to the need to implement bipolar velocity encoding gradients. PC using steady‐state free precession (SSFP) has recently been developed to acquire PC data at higher rate

Time-resolved three-dimensional (3D) pha
✍ Francesco Santini; Stephan G. Wetzel; Jelena Bock; Michael Markl; Klaus Scheffle 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 711 KB

## Abstract In this study the feasibility of a time‐resolved, three‐dimensional (3D), three‐directional flow‐sensitive balanced steady‐state free precession (bSSFP) sequence is demonstrated. Due to its high signal‐to‐noise ratio (SNR) in blood and cerebrospinal fluid (CSF) this type of sequence is

Balanced phase-contrast steady-state fre
✍ M. Markl; M.T. Alley; N.J. Pelc 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 657 KB

## Abstract A technique for measuring velocity is presented that combines cine phase contrast (PC) MRI and balanced steady‐state free precession (SSFP) imaging, and is thus termed PC‐SSFP. Flow encoding was performed without the introduction of additional velocity encoding gradients in order to kee

Reduction in flow artifacts by using int
✍ Yasuo Amano; Astushi Nozaki; Katsuya Takahama; Tatuso Kumazaki 📂 Article 📅 2005 🏛 Elsevier Science 🌐 English ⚖ 171 KB

Balanced steady-state free precession (SSFP) magnetic resonance (MR) imaging is feasible for cine cardiac images because of the high contrast between myocardium and blood pool and robustness to rapid blood flow. Nonetheless, the flow artifacts are often observed because of off-resonance effects and