𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Time-resolved three-dimensional (3D) phase-contrast (PC) balanced steady-state free precession (bSSFP)

✍ Scribed by Francesco Santini; Stephan G. Wetzel; Jelena Bock; Michael Markl; Klaus Scheffler


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
711 KB
Volume
62
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

In this study the feasibility of a time‐resolved, three‐dimensional (3D), three‐directional flow‐sensitive balanced steady‐state free precession (bSSFP) sequence is demonstrated. Due to its high signal‐to‐noise ratio (SNR) in blood and cerebrospinal fluid (CSF) this type of sequence is particularly effective for acquisition of blood and CSF flow velocities. Flow sensitivity was achieved with the phase‐contrast (PC) technique, implementing a custom algorithm for calculation of optimal gradient parameters. Techniques to avoid the most important sources of bSSFP‐related artifacts (including distortion due to eddy currents and signal voids due to flow‐related steady‐state disruption) are also presented. The technique was validated by means of a custom flow phantom, and in vivo experiments on blood and CSF were performed to demonstrate the suitability of this sequence for human studies. Accurate depiction of blood flow in the cerebral veins and of CSF flow in the cervical portion of the neck was obtained. Possible applications of this technique might include the study of CSF flow patterns, direct in vivo study of pathologies such as hydrocephalus and Chiari malformation, and validation for the existing CSF circulation model. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Balanced phase-contrast steady-state fre
✍ M. Markl; M.T. Alley; N.J. Pelc 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 657 KB

## Abstract A technique for measuring velocity is presented that combines cine phase contrast (PC) MRI and balanced steady‐state free precession (SSFP) imaging, and is thus termed PC‐SSFP. Flow encoding was performed without the introduction of additional velocity encoding gradients in order to kee

Measuring aortic diameter with different
✍ Silke Potthast; Lee Mitsumori; Luana A. Stanescu; Michael L. Richardson; Kelley 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 373 KB 👁 1 views

## Abstract ## Purpose: To compare nongated three‐dimensional (3D) contrast‐enhanced magnetic resonance angiography (CE‐MRA) with 3D‐navigated cardiac‐gated steady‐state free‐precession bright blood (3D‐nav SSFP) and noncontrast 2D techniques for ascending aorta dimension measurements. ## Materia

Non-contrast-enhanced MR portography wit
✍ Kotaro Shimada; Hiroyoshi Isoda; Tomohisa Okada; Toshikazu Kamae; Shigeki Arizon 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 482 KB

## Abstract ## Purpose To compare and evaluate images acquired with two different MR angiography (MRA) sequences, three‐dimensional (3D) half‐Fourier fast spin‐echo (FSE) and 3D true steady‐state free‐precession (SSFP) combined with two time‐spatial labeling inversion pulses (T‐SLIPs), for selecti