𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Improved analysis of 1H-MR spectra in the presence of mobile lipids

✍ Scribed by Dorothee P. Auer; Christoff Gössl; Timo Schirmer; Michael Czisch


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
120 KB
Volume
46
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Focal brain lesions can be associated with proton magnetic resonance spectra (^1^H‐MRS)‐detectable mobile lipids, reflecting severe tissue degradation and necrosis. However, advanced fitting procedures, such as the LCModel, fail to adequately fit spectra in the presence of lipid resonances. To overcome this, different approaches to generate lipid model spectra were compared using a phantom, real in vivo data, and simulated data. Twenty‐six in vivo short‐echo time (TE) ^1^H‐MRS from
21 malignant gliomas, four infections, and one ischemia were analyzed to evaluate the performance of the modified LCModel fit. Adding simulated aliphatic resonances at 1.3 and 0.9 ppm improved the overall fitting quality remarkably and allowed good separation of lactate and alanine. Also, a better differentiation of glioblastomas and anaplastic gliomas was achieved. In conclusion, we propose a simple way to efficiently include lipid resonances in the LCModel, allowing a better fit of in vivo short‐TE ^1^H‐MRS, and demonstrate the diagnostic potential of quantitative assessment of mobile lipids in brain tumors. Magn Reson Med 46:615–618, 2001. © 2001 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


1H MRS studies of signals from mobile li
✍ Antonella Rosi; Sveva Grande; Anna Maria Luciani; Piero Barone; Vladimir Mlynari 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 266 KB 👁 1 views

## Abstract ^1^H magnetic resonance studies on MCF‐7 and HeLa cells were undertaken to reveal differences in lipid and lipid metabolite signals during the growth in culture. High intensity mobile lipid (ML) signals were found during the first days in culture, while afterwards the same signals decli

Representation of strong baseline contri
✍ Brian J. Soher; Karl Young; Andrew A. Maudsley 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 170 KB

A comparison is made between two optimization procedures and two data models for automated analysis of in vivo proton MR spectra of brain, typical of that obtained using MR spectroscopic imaging at 1.5 Tesla. First, a shift invariant wavelet filter is presented that provides improved performance ove

1H MRS in the rat brain under pentobarbi
✍ Isabelle Iltis; Małgorzata Marjańska; Fei Du; Dee M. Koski; Xiao-Hong Zhu; Kâmil 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 245 KB 👁 1 views

## Abstract Commercial solutions for pentobarbital anesthesia typically contain water, ethanol, and propylene glycol (PG). The last two are characterized by resonances that can affect the determination of metabolite concentrations from ^1^H spectra. The purpose of the present study was to measure t

1H MR Spectroscopy Detection of Lipids a
✍ Paul E. Sijens; Peter C. Levendag; Charles J. Vecht; Pieter van Dijk; Matthijs O 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 689 KB

H MR spectroscopy was used to correlate the metabolite signals in 60 untreated metastatic brain tumors with the results of Gd-DTPA enhanced MRI. Cubic volumes containing brain metastases of lung cancer ( n = 17), mammary carcinoma (n=24), melanoma (n = 12) and those originating from other tumors (n=

Characterization of the macromolecule ba
✍ L. Hofmann; J. Slotboom; C. Boesch; R. Kreis 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 230 KB

## Abstract Short‐echo‐time magnetic resonance spectra of human brain contain broad contributions from macromolecules. As they are a priori of unknown shape and intensity, they pose a problem if one wants to quantitate the overlying spectral features from low‐molecular‐weight metabolites. On the ot