The purpose of this study was to explore systematically the effect of the imaging parameters changeable by the user in spin‐echo (SE) imaging sequences to minimize image distortion when imaging joint prostheses. A titanium alloy hip joint prosthesis was studied at 1.0 T. The SE imaging parameters were bandwidth/pixel (BW/p), TE, strength of encoding gradients (matrix size), echo train length (ETL), and direction of phase and frequency encoding. The effect of ETL in rapid acquisition relaxation enhanced (RARE) sequences was also evaluated with a turbo‐SE sequence using a different ETL with the same TR and an effective TE. It is concluded that an optimized image quality can be achieved in SE imaging by using a high bandwidth/pixel value (at least 130 Hz/pixel), a high resolution matrix (256–512), sequences with multiple refocusing, and a frequency‐encoding axis parallel to the long axis of the prosthesis. The degree of distortion is reduced with this optimized technique.


📜 SIMILAR VOLUMES


Accelerated dynamic MR imaging with a pa
✍ Nobuyuki Takahashi; Hiroshi Yoshioka; Masayuki Yamaguchi; Yukihisa Saida; Yuji I 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 636 KB

## Abstract ## Purpose To assess the impact of the accelerated dynamic MR imaging (ADMRI) approach using parallel imaging for detecting hypervascular hepatocellular carcinomas (HCCs) and to evaluate the usefulness of a test bolus in examination and subtraction imaging in this setting. ## Material

Imaging of finger joints in a whole-body
✍ Helmut Rumpel; Wilfred C.G. Peh 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 162 KB

## Abstract This work considers the design and operation of a solenoid radiofrequency (RF) coil for magnetic resonance (MR) mini‐imaging of finger joints using a whole‐body system. The considerations were focused on the requirements of high sensitivity, easy patient access, and cost‐effectiveness.

Assessment of proximal finger joint infl
✍ Alexander K. Scheel; Andreas Krause; Ingolf Mesecke-von Rheinbaben; Georg Metzge 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 289 KB 👁 2 views

## Abstract ## Objective To evaluate a newly developed laser‐based imaging technique for the study of soft tissue changes and acute inflammatory processes of the proximal interphalangeal (PIP) joints in patients with rheumatoid arthritis (RA). ## Methods A novel imaging device was developed whic

Further steps toward direct magnetic res
✍ Gaby S. Pell; David F. Abbott; Steven W. Fleming; James W. Prichard; Graeme D. J 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 449 KB

## Abstract The characteristics of an MRI technique that could be used for direct detection of neuronal activity are investigated. It was shown that magnitude imaging using echo planar imaging can detect transient local currents. The sensitivity of this method was thoroughly investigated. A partial

Six DOF in vivo kinematics of the ankle
✍ Richard J. de Asla; Lu Wan; Harry E. Rubash; Guoan Li 📂 Article 📅 2006 🏛 Elsevier Science 🌐 English ⚖ 264 KB

## Abstract Accurate knowledge of in vivo ankle joint complex (AJC) biomechanics is critical for understanding AJC disease states and for improvement of surgical treatments. This study investigated 6 degrees‐of‐freedom (DOF) in vivo kinematics of the human AJC using a combined dual‐orthogonal fluor