Matrix-assisted laser desorption/ionization time-of-flight mass spectra of proteins in cerebrospinal fluid analyzed without prior purification are presented. Less than 100 fmol amounts of proteins in the 10 000 to 20 000 u mass range and linked to human disease (multiple sclerosis, Alzheimer's disea
Identification of two-dimensionally separated human cerebrospinal fluid proteins by N-terminal sequencing, matrix-assisted laser desorption/ionization — mass spectrometry, nanoliquid chromatography-electrospray ionization-time of flight-mass spectrometry, and tandem mass spectrometry
✍ Scribed by Jos Raymackers; Annick Daniels; Veronique De Brabandere; Carla Missiaen; Martine Dauwe; Peter Verhaert; Eugeen Vanmechelen; Lydie Meheus
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 576 KB
- Volume
- 21
- Category
- Article
- ISSN
- 0173-0835
No coin nor oath required. For personal study only.
✦ Synopsis
Identification of two-dimensionally separated human cerebrospinal fluid proteins by N-terminal sequencing, matrix-assisted laser desorption/ ionization ± mass spectrometry, nanoliquid chromatography-electrospray ionization-time of flight-mass spectrometry, and tandem mass spectrometry Optimal application of biological mass spectrometry (MS) in combination with twodimensional polyacrylamide gel electrophoresis (2-D PAGE) of human cerebrospinal fluid (CSF) can lead to the identification of new potential biological markers of neurological disorders. To this end, we analyzed a number of 2-D PAGE protein spots in a human CSF pool using spot co-localization, N-terminal sequencing, matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) and nanoliquid chromatography-electrospray ionization-time of flight-mass spectrometry (nanoLC-ESI-TOF-MS) with tandem MS switching. Our constructed CSF master contained 469 spots after image analysis and processing of 2-D gels. Upon visual inspection of our CSF master with the CSF pattern available on the ExPASy server, it was possible to locate and annotate 15 proteins. N-terminal sequence analysis and MALDI-MS peptide mass fingerprint analysis of both silver-and Coomassie Brilliant Blue (CBB) G-250-stained protein spots after in situ trypsin digest not only confirmed nine of the visually annotated spots but additionally resolved the identity of another 13 spots. Six of these proteins were not annotated on the 2-D ExPASy map: complement C3 a-chain (1321±1663), complement factor B, cystatin C, calgranulin A, hemoglobin b-chain, and b-2-microglobulin. It was clear that MALDI-MS identification from CBB G-250-stained, rather than from silver-stained, spots was more successful. In cases where no N-terminal sequence and/or no clear MALDI-MS result was available, nanoLC-ESI-TOF-MS and tandem MS automated switching was used to clarify and/or identify these protein spots by generating amino acid sequence tags. In addition, enrichment of the concentration of low-abundant proteins on 2-D PAGE was obtained by removal of albumin and immunoglobulins from the CSF pool using affinity chromatography. Subsequent analysis by 2-D PAGE of the fractionated CSF pool showed various new silver-stainable protein spots, of which four were identified by nanoLC-ESI-TOF-MS and tandem MS switching. No significant homology was found in either protein or DNA databases, indicating than these spots were unknown proteins.
📜 SIMILAR VOLUMES
## Abstract A prototype matrix‐assisted laser desorption/ionization quadrupole time‐of‐flight (MALDI‐QqTOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine‐, phosphothreonine‐ and phosphoserine‐containing peptides. The high mass resolution and mass accuracy of the instrume
Oligonucleotide sequencing by fragmentation in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry has been demonstrated. With this sequencing method, the preparation of oligonucleotide ladder products and gel electrophoresis are not required, thus the sequencing
Several species of the genus Haemophilus are well known etiological agents of pneumonia, meningitis, conjunctivitis, epiglottitis and chancroid. However, identiÐcation and speciation of Haemophilus is both time consuming and labor intensive. Matrix-assisted laser desorption/ionization time-of-Ñight
## Abstract The development is described of a rapid, simply and accurate analytical method aimed at evaluating both the presence of cow milk in either raw ewe and water buffalo milk samples employed in industrial processes and the addition of powdered milk to samples of fresh raw milk, using matrix