Hydrogen induced cracking (HIC) of line pipe steel was investigated through immersion testing and hydrogen permeation measurements. At constant pH and hydrogen sulphide partial pressure (pH 2 S), the extent of HIC was found to depend on exposure time until a stable level was reached. The time to rea
✦ LIBER ✦
Hydrogen induced cracking (HIC) testing of low alloy steel in sour environment: Impact of time of exposure on the extent of damage
✍ Scribed by Jean Kittel; Véronique Smanio; Marion Fregonese; Laurence Garnier; Xavier Lefebvre
- Book ID
- 116385465
- Publisher
- Elsevier Science
- Year
- 2010
- Tongue
- English
- Weight
- 831 KB
- Volume
- 52
- Category
- Article
- ISSN
- 0010-938X
No coin nor oath required. For personal study only.
📜 SIMILAR VOLUMES
Hydrogen induced cracking (HIC) testing
✍
Jean Kittel; Véronique Smanio; Marion Fregonese; Laurence Garnier; Xavier Lefebv
📂
Article
📅
2010
🏛
Elsevier Science
🌐
English
⚖ 831 KB
Testing the resistance of welds in low-a
✍
H. Pircher; G. Sussek
📂
Article
📅
1987
🏛
Elsevier Science
🌐
English
⚖ 658 KB
Effects of alloying elements, microstruc
✍
F. Huang; X. G. Li; J. Liu; Y. M. Qu; C. W. Du
📂
Article
📅
2010
🏛
John Wiley and Sons
🌐
German
⚖ 925 KB
## Abstract Hydrogen induced cracking (HIC) behavior of X120 pipeline steel with different amounts of Mn and Al was investigated using NACE standard TM0284‐2005 and back‐scattered electron imaging (BSE). The results demonstrated that inclusions and microstructure play significant roles in HIC susce