๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Hydride Generation Graphite Furnace Atomic Absorption Determination of Bismuth in Clinical Samples with in Situ Preconcentration

โœ Scribed by H. Matusiewicz; M. Kopras; A. Suszka


Publisher
Elsevier Science
Year
1995
Tongue
English
Weight
447 KB
Volume
52
Category
Article
ISSN
0026-265X

No coin nor oath required. For personal study only.

โœฆ Synopsis


A sensitive method for the determination of bismuth in clinical samples using hydride generation/ trapping and atomization in a graphite furnace is described. Addition of (\mathrm{Pd}-\mathrm{Ir}) to the furnace tube surface before hydride trapping leads to great improvement in the sensitivity of the method. Calibration is achieved with simple aqueous standards carried through this same procedure. An absolute detection limit ((3 \sigma)) of (100 \mathrm{pg}) and a concentration detection limit of (20 \mathrm{ng} /) liter are obtained using (5-\mathrm{ml}) sample volumes. Corresponding precisions of 8-12% are typical for analyses of these samples. Microwave-assisted sample digestion procedures using (\mathrm{HNO}{3}) and (\mathrm{H}{2} \mathrm{O}_{2}) were used to decompose clinical materials. The method was used to determine Bi in human blood, serum, urine, and tissue before and after intake of therapeutic doses of colloidal bismuth citrale. tyes Academic Press, Inc.


๐Ÿ“œ SIMILAR VOLUMES


Determination of Cadmium in Wines Using
โœ James Jaganathan; Alan L. Reisig; Sumer M. Dugar ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 77 KB

A graphite furnace atomic absorption spectrometry method with Zeeman background correction for the direct determination of cadmium in grape wines is described. Use of ammonium dihydrogen phosphate, magnesium nitrate, and palladium nitrate as matrix modifiers was investigated. Palladium nitrate with

Automatic on-line preconcentration syste
โœ Zhen-Shan Liu; Shang-Da Huang ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 444 KB

An automatic on-line preconcentration system for graphite furnace atomic absorption spectrometty (GFAAS) for the determination of trace metals in sea water was developed. This system was modified from a Perkin-Elmer AS-40 autosampler by mounting a silica gel Crs microcolumn near the tip of the autom

Investigation of Stable Coatings forin S
โœ Y.-p. Liao; H.O. Haug ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 127 KB

Flow-injection hydride generation and in situ concentration of Se and Te hydrides in graphite furnace atomic absorption spectrometry (AAS) can be automated using a highly stable trapping reagent replacing the Pd modifier. In a systematic study, carbide-forming elements (Zr, Nb, Ta, W) and noble meta