The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantatio
## Abstract The purpose of this study was to evaluate the influence of the oxidized surface on boneβtoβimplant contact (BIC%), the bone density in the threaded area (BA%), as well as the bone density outside the threaded area (BD%) in human jaws after 2 months of unloaded healing. Thirteen subjects