๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Histological and histomorphometrical evaluation of the bone reaction to three different titanium alloy and hydroxyapatite coated implants

โœ Scribed by J. A. Jansen; J. P. C. M. van der Waerden; J. G. C. Wolke


Publisher
Wiley (John Wiley & Sons)
Year
1993
Tongue
English
Weight
770 KB
Volume
4
Category
Article
ISSN
1045-4861

No coin nor oath required. For personal study only.

โœฆ Synopsis


The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantation times were 6 and 16 weeks. The histological evaluation included measurement of the amount of bone apposition and analysis of the bone reaction and interface characteristics around the implants. The results demonstrated no marked differences in bony reaction to the different implant materials. In addition, the HA coatings showed loss of thickness.


๐Ÿ“œ SIMILAR VOLUMES


Histomorphometrical and mechanical evalu
โœ Vercaigne, S. ;Wolke, J. G. C. ;Naert, I. ;Jansen, J. A. ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 519 KB

The aim of this study was to investigate the biological and mechanical response of bone to titanium plasmasprayed implants of different roughnesses. Three types of titanium plasma-spray coating were applied to beamshaped implants: Ti2, Ti3, and Ti4, with a Ra of 16.5, 21.4, and 37.9 m, respectively.

A histological and histomorphometrical e
โœ Caulier, H. ;van der Waerden, J. P. C. M. ;Wolke, J. G. C. ;Kalk, W. ;Naert, I. ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 512 KB

Various studies already have shown that the occurrence of oral implant failure is higher in the maxilla than in the mandible. To learn whether Ca-P coatings can improve the success rate of oral implants in the maxilla, three different plasma-sprayed, Ca-P-coated, self-tapping Brรฅnemark implants were

The effect of different titanium and hyd
โœ Knabe, Christine ;Howlett, Cameron Rolfe ;Klar, Falk ;Zreiqat, Hala ๐Ÿ“‚ Article ๐Ÿ“… 2004 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 199 KB ๐Ÿ‘ 1 views

## Abstract Roughened titanium (Ti) surfaces have been widely used for dental implants. In recent years, there has been the tendency to replace Ti plasmaโ€sprayed surfaces by sandblasted and acidโ€etched surfaces in order to enhance osseous apposition. Another approach has been the utilization of hyd