## Abstract In this study, a high‐throughput and high‐sensitivity profiling system for β‐cryptoxanthin (βCX) and β‐cryptoxanthin fatty acid ester (βCXFA) was constructed by supercritical fluid chromatography (SFC) coupled with triple quadrupole mass spectrometry (QqQMS). βCX and nine βCXFAs were su
Highly sensitive and accurate profiling of carotenoids by supercritical fluid chromatography coupled with mass spectrometry
✍ Scribed by Atsuki Matsubara; Takeshi Bamba; Hiroki Ishida; Eiichiro Fukusaki; Kazumasa Hirata
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 731 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
We attempted to establish a high‐speed and high‐resolution profiling method for a carotenoid mixture as a highly selective and highly sensitive detection method; the analysis was carried out by supercritical fluid chromatography (SFC) coupled with mass spectrometry (MS). When an octadecyl‐bonded silica (ODS) particle‐packed column was used for separation, seven carotenoids including structural isomers were successfully separated within 15 min. This result indicated not only improved separation but also improved throughput compared to the separation and throughput in RP‐HPLC. The use of a monolithic ODS column resulted in additional improvement in both the resolution and the throughput; the analysis time was reduced to 4 min by increasing the flow rate. Furthermore, carotenoids in biological samples containing the complex matrices were separated effectively by using several monolithic columns whose back pressure was very low. The mass spectrometer allowed us to perform a more sensitive analysis than UV detection; the detection limit of each carotenoid was 50 pg or below. This is the first report of carotenoid analysis carried out by SFC‐MS. The profiling method developed in this study will be a powerful tool for carrying out accurate profiling of biological samples.
📜 SIMILAR VOLUMES
## Abstract We established a high‐throughput and high‐resolution analytical method based on supercritical fluid chromatography (SFC) coupled with mass spectrometry (MS) for the simultaneous profiling of diverse polar lipids in a mixture. Trimethylsilyl (TMS) derivatization was used for the analysis
## Abstract Bisphenol A (BPA) is one of the environmental endocrine‐disrupting chemicals used widely in common consumer products. There is an increasing concern about human exposure to BPA, particularly in fetuses, due to the potential adverse effects related to the estrogenic activity of BPA. In a