Bisphenol A (BPA) is one of the environmental endocrine‐disrupting chemicals used widely in common consumer products. There is an increasing concern about human exposure to BPA, particularly in fetuses, due to the potential adverse effects related to the estrogenic activity of BPA. In assessing environmental exposure to BPA, it is essential to have a sensitive, accurate, and specific analytical method, particularly for low BPA levels in complex sample matrices. In this study, we developed and validated an accurate, sensitive, and robust liquid chromatography–mass spectrometry (LC‐MS) method for determining the BPA concentrations in human amniotic fluid (AF). In this method, BPA and the internal standards ^13^C~12~‐BPA were extracted from 500 μL of human AF using solid‐phase extraction. Calibration curves were linear over a concentration range of 0.3–100 ng/mL for BPA. The analytes were quantitatively determined using LC‐MS operated in a negative electrospray ionization selected ion monitoring mode. This validated method has been used successfully in the clinical sample analysis of BPA in second‐trimester AF specimens.


📜 SIMILAR VOLUMES


Determination of di-(2-ethylhexyl)phthal
✍ Antonia Garrido Frenich; María de las Nieves Barco Bonilla; Juan Carlos López Ma 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 497 KB

## Abstract Di‐(2‐ethylhexyl)phthalate (DEHP) was determined in environmental samples such as water and soil. DEHP was extracted from water samples using SPE, whereas for soils pressurized liquid extraction was applied as extraction method, using hexane/acetone (1:1, v/v) as extractant solvent. The

Determination of LTE4 in Human Urine By
✍ Wu, Yunhui; Li, Lily Y.-T.; Henion, Jack D.; Krol, George J. 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 578 KB

A sensitive and specific high-performance liquid chromatographic/ionspray tandem mass spectrometric (LC/ionspray MS/MS) method was developed and validated to quantitate leukotriene E, (LTE,) in human urine. This method involves solid-phase extraction with Empore membrane disks to isolate LTE, and it

Determination of vitamin B5 in human uri
✍ Olivier Heudi; Patric Fontannaz 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 404 KB

In the present work, we have developed a simple and rapid liquid chromatography/mass spectrometry (LC/MS) method for the identification and quantification of vitamin B5 in human urine. Urine was spiked with vitamin B5 internal standard, hopantenic acid (HOPA), and then diluted with the LC mobile pha

Quantitative Determination of Saccharide
✍ Gejing Deng; Denise Chow; Gautam Sanyal 📂 Article 📅 2001 🏛 Elsevier Science 🌐 English ⚖ 92 KB

A direct and highly selective method, combining liquid chromatography (LC) with electrospray ionization mass spectrometry (ESI-MS), has been developed for quantifying saccharide surfactants. Saccharide surfactants, such as n-octyl-beta-d-glucopyranoside (NOG), are widely used to solubilize or refold

Determination of paraquat and diquat in
✍ Xiao-Pen Lee; Takeshi Kumazawa; Masaya Fujishiro; Chika Hasegawa; Tetsuya Arinob 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 114 KB 👁 2 views

## Abstract Paraquat (PQ) and diquat (DQ) in human whole blood and urine were analyzed by high‐performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization (ESI). The compounds were extracted with Sep‐Pak C~18~ cartridges from whole blood and uri