High resolution noncontrast MRI of the hip
β Scribed by Hollis G. Potter; Jennifer Schachar
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 655 KB
- Volume
- 31
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
The relatively thin cartilage of the hip joint, as well as its complex geometry, poses challenges for standardized, reproducible assessment of cartilage and the acetabular labrum. With appropriate pulse sequence parameters, however, accurate, reproducible assessment of cartilage and the labrum is feasible. More detailed evaluation of cartilage biochemistry may be obtained with techniques aimed at noninvasively evaluating the integrity of collagen and/or proteoglycan components in the articular cartilage. One of the benefits of noncontrast techniques lie in the ability to visualize the native synovium, and thereby detect the presence of synovial proliferative disorders, the clinical symptoms of which may mimic a labral tear or traumatic cartilage injury. Standard cartilage evaluation allows for the detection of surface delamination and osteoarthritis in the setting of femoroacetabular impingement, as well as subtle areas of subchondral collapse and secondary delamination of cartilage in the setting of osteonecrosis. This preserves the use of hip arthroscopy as a therapeutic rather than a diagnostic tool. J. Magn. Reson. Imaging 2010; 31: 268β278. Β©2010 WileyβLiss, Inc.
π SIMILAR VOLUMES
Hip ultrasound was performed on 44 children (114 exams) presenting with a painful hip or a limp thought to be due to hip disease. Effusions were found in 20 patients (21 hips). Hip ultrasound in combination with aspiration of the joint was found to be useful in diagnosis of osteomyelitis and septic
## Abstract The development of heart failure (HF) is an evolving process that entails both structural and functional changes through time. While the physiological state of cardiac pathologies has been well characterized, less is known about the transition from a normal to a maladaptive state. Magne
## Abstract ## Purpose To describe an initial experience imaging the human hippocampus in vivo using a 7T magnetic resonance (MR) scanner and a protocol developed for very high field neuroimaging. ## Materials and Methods Six normal subjects were scanned on a 7T whole body MR scanner equipped wi
## Abstract We applied dualβflex coils in a phasedβarray configuration to obtain high resolution MR images of the bilateral hips and compared the image quality with nonβphasedβarray imaging. Multiple fast spinβecho images of both hips were obtained in a single acquisition. Two consecutive acquisiti