✦ Synopsis


A novel protocol for three-station MR angiography (MRA) of the lower extremities is described. A time-resolved undersampled projection reconstruction (PR) acquisition was used to image the calf station during a first injection, and non-time-resolved PR acquisitions were used with the bolus-chase technique to image the abdomen and thigh stations during a second injection. The streak artifacts resulting from undersampling the PR data were reduced with the use of a spatial Fermi filter based on the sensitivity of each coil element in a peripheral vascular phased-array coil. This novel technique provided high spatial resolution and a broad range of coverage, and depicted the contrast dynamics in the most distal station of the lower extremities.


📜 SIMILAR VOLUMES


Contrast-enhanced peripheral magnetic re
✍ Jiang Du; Timothy J. Carroll; Ethan Brodsky; Aiming Lu; T.M. Grist; Charles A. M 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 528 KB

## Abstract ## Purpose To investigate the application of time‐resolved vastly undersampled isotropic projection reconstruction (VIPR) in contrast‐enhanced magnetic resonance angiography of the distal extremity (single station), and peripheral run‐off vasculature in the abdomen, thigh, and calf (th

High-resolution continuously acquired pe
✍ Michael O. Zenge; Florian M. Vogt; Katja Brauck; Michaela Jökel; Joerg Barkhause 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 537 KB

## Abstract Continuously‐moving‐table MRI, in contrast to traditional multistation techniques, potentially can improve the scan time efficiency of whole‐body applications and provide seamless images of an extended field of view (FOV). Contrast‐enhanced MR angiography (CE‐MRA) in particular requires

Time-resolved undersampled projection re
✍ Jiang Du; Aiming Lu; Walter F. Block; Francis J. Thornton; Thomas M. Grist; Char 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 428 KB

## Abstract The hybrid projection reconstruction (PR) imaging provides high temporal resolution through an undersampled PR acquisition for the in‐plane dimensions and Cartesian slice encoding for the through‐plane dimension. The undersampling of projection data introduces streak artifact, which may

Time-resolved, undersampled projection r
✍ J. Du; T.J. Carroll; H.J. Wagner; K. Vigen; S.B. Fain; W.F. Block; F.R. Korosec; 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 753 KB

Imaging of the blood vessels below the knee using contrast-enhanced (CE) MRI is challenging due to the need to coordinate image acquisition and arrival of the contrast in the targeted vessels. Time-resolved acquisitions have been successful in consistently capturing images of the arterial phase of t

Maximizing contrast-to-noise ratio in ul
✍ Maisie S. Wang; David R. Haynor; Gregory J. Wilson; Tim Leiner; Jeffrey H. Maki 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 554 KB

## Abstract ## Purpose To determine sequence parameters that maximize vascular contrast‐to‐noise (CNR) for ultra‐high resolution equilibrium phase (EP) peripheral imaging for the blood pool agent (BPA) Vasovist. ## Materials and Methods A model for maximizing CNR in EP MR angiography (MRA) is pr