𝔖 Bobbio Scriptorium
✦   LIBER   ✦

High-resolution computed tomography of lobster (Panulirus interruptus) stomach

✍ Scribed by Kevin H. Hobbs; Scott L. Hooper


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
788 KB
Volume
270
Category
Article
ISSN
0362-2525

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

We used micro computed tomography to produce a high‐resolution density image of the lobster (Panulirus interruptus) stomach and identified on this image the previously defined stomach ossicles. These data are the first coordinate‐based, three‐dimensional description of the stomach and are a necessary first step for developing biomechanical models of it. They are also interesting for several reasons in their own right. First, the ossicles showed large shape and density variations. These data suggest that different ossicles may serve different functions, with some acting as force‐delivering levers, some as spring‐like elements, and some as wall‐like elements that resist internal stomach pressure or function as two‐dimensional force‐delivering plates. Second, large intra‐ossicle density variations were present in individual ossicles, reminiscent of I‐beams, oval bicycle frames, and similar mass‐minimizing structural elements, suggesting that evolution has minimized ossicle mass and identifying which ossicle regions are most likely important in force delivery. Third, joints appeared to be either continuous density interconnections without distinct separations between the ossicles or ‘floating’ joints in which the ends of the two ossicles were separated by relatively large distances spanned by connective tissue. In these latter joints, although the distance between ossicle ends is likely maintained at a relatively constant value, a wide range of ossicle angles would thus be theoretically possible. Notably absent are close‐apposition, morphologically specialized joints such as hinge or ball‐and‐socket joints. J. Morphol. 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


High resolution computed tomography in e
✍ Swartz, Joel D. ;Russell, Kamal B. ;Wolfson, Robert J. ;Marlowe, Frank I. 📂 Article 📅 1984 🏛 Wiley (John Wiley & Sons) ⚖ 579 KB

## Abstract High resolution computed tomography has completely replaced conventional multidirectional tomography in the evaluation of the temporal bone. Unprecedented detail is now available for evaluation of both middle ear and inner ear structures. A sampling of our experience in the evaluation o

High resolution computed tomography: Par
✍ Swartz, Joel D. ;Abaza, Nabil A, ;Hendler, Barry H. ;Tidwell, Otto ;Popky, Georg 📂 Article 📅 1985 🏛 Wiley (John Wiley & Sons) ⚖ 562 KB

High resolution computed tomography (CT) has been a mainstay in the preoperative evaluation of odontogenic lesions. Unsurpassed bony detail is complemented by exquisite delineation of t h e soft tissue mass itself. Our experience with these lesions is presented. Selected illustrations are supplement

High-resolution X-ray computed tomograph
✍ Joyce A. Parga; Murat Maga; Deborah J. Overdorff 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 364 KB

## Abstract In this study, high‐resolution computed tomography X‐ray scanning was used to scan ring‐tailed lemur (__Lemur catta__) copulatory plugs. This method produced accurate measures of plug volume and surface area, but was not useful for visualizing plug internal structure. Copulatory plug si

High resolution computed tomography, Par
✍ Swartz, Joel D. ;Korsvik, Holly ;Saluk, Patricia H. ;Popky, George L. 📂 Article 📅 1984 🏛 Wiley (John Wiley & Sons) ⚖ 848 KB

Normal and pathologic anatomy of the soft tissues of the neck is clearly delineated with high resolution computed tomography (CT). The CT densities of soft tissues, fat, and enhanced blood vessels are strikingly different from each other and, therefore, mass lesions are clearly discernable. Often, a

High-resolution computed tomography for
✍ Judith R. Tate; Christopher E. Cann 📂 Article 📅 1982 🏛 John Wiley and Sons 🌐 English ⚖ 615 KB

## Abstract Special methods have been developed to use computed tomography (CT) for 3‐dimensional imaging of both fossil and extant bones. Most commercial CT scanners cannot display the internal structure of fossils because the very high density is beyond the upper limits of the normal CT number sc

Improved reproducibility of high-resolut
✍ Joshua A. MacNeil; Steven K. Boyd 📂 Article 📅 2008 🏛 Elsevier Science 🌐 English ⚖ 770 KB

A human high-resolution peripheral quantitative computed tomography scanner (HR-pQCT) (XtremeCT, Scanco Medical, Switzerland) capable of measuring three important indicators of bone quality (micro-architectural morphology, mineralization and mechanical stiffness) has been developed. The goal of this