𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality

✍ Scribed by Joshua A. MacNeil; Steven K. Boyd


Publisher
Elsevier Science
Year
2008
Tongue
English
Weight
770 KB
Volume
30
Category
Article
ISSN
1350-4533

No coin nor oath required. For personal study only.

✦ Synopsis


A human high-resolution peripheral quantitative computed tomography scanner (HR-pQCT) (XtremeCT, Scanco Medical, Switzerland) capable of measuring three important indicators of bone quality (micro-architectural morphology, mineralization and mechanical stiffness) has been developed. The goal of this study was to evaluate the reproducibility of male and female HR-pQCT in vivo measurements, and elucidate the causes of error in these measurements through a comparison with in vitro measurements. The best possible short-term reproducibility was found using a set of 10 in vitro measurements without repositioning, and a set of 10 with repositioning. Subsequently, in vivo measurements were performed on 15 male and 15 female subjects at baseline and follow-ups of 1 week and 4 months to determine the short- and long-term reproducibility of the system. In addition to the 2D area matching method used in the standard evaluation protocol, a custom developed 3D registration method was used to find the common region between repeated scans. The best possible reproducibility without movement artifacts and repositioning error was less than 0.5%, while the reproducibility with repositioning error was less than 1.5%. The in vivo reproducibility of density (<1%), morphological (<4.5%) and stiffness (<3.5) measurements was consistently poorer than the reproducibility of cadaver measurements, presumably due to small movement artifacts and repositioning errors. Using 3D image registration, repositioning error was reduced on average by 23% and 8% for measurements of the radius and tibia sites, respectively. This study has provided bounds for the reproducibility of HR-pQCT to monitor bone quality longitudinally, and a basis for clinical study design to determine detectable changes.


πŸ“œ SIMILAR VOLUMES


High-resolution computed tomography for
✍ Judith R. Tate; Christopher E. Cann πŸ“‚ Article πŸ“… 1982 πŸ› John Wiley and Sons 🌐 English βš– 615 KB

## Abstract Special methods have been developed to use computed tomography (CT) for 3‐dimensional imaging of both fossil and extant bones. Most commercial CT scanners cannot display the internal structure of fossils because the very high density is beyond the upper limits of the normal CT number sc

Bone strength measured by peripheral qua
✍ Yahtyng Sheu; Joseph M Zmuda; Robert M Boudreau; Moira A Petit; Kristine E Ensru πŸ“‚ Article πŸ“… 2010 πŸ› American Society for Bone and Mineral Research 🌐 English βš– 97 KB πŸ‘ 2 views

Many fractures occur in individuals without osteoporosis defined by areal bone mineral density (aBMD). Inclusion of other aspects of skeletal strength may be useful in identifying at-risk subjects. We used surrogate measures of bone strength at the radius and tibia measured by peripheral quantitativ