## High performance liquid chromatography of acarbose and its metabolite on porous graphitic carbon column This paper describes the development of an analytical method for the determination of two pseudo-oligosaccharides, acarbose and its main metabolite. The analysis was carried out by liquid chr
High-Performance Liquid Chromatography of Glycopeptides and Oligosaccharides on Graphitized Carbon Columns
β Scribed by J.Q. Fan; A. Kondo; I. Kato; Y.C. Lee
- Publisher
- Elsevier Science
- Year
- 1994
- Tongue
- English
- Weight
- 477 KB
- Volume
- 219
- Category
- Article
- ISSN
- 0003-2697
No coin nor oath required. For personal study only.
β¦ Synopsis
High-performance liquid chromatography of carbohydrate materials on graphitized carbon columns (GCC) has some advantages over other types of chromatography. Oligosaccharides and glycopeptides with few amino acids are barely retained on reversed-phase columns even under high salt or low pH conditions, but can be retained effectively on a graphitized carbon column. Moreover, elution of GCC requires concentrations of organic solvents lower than that required for normal-phase columns. The usefulness of graphitized carbon columns is exemplified by the following results: (i) Man9GlcNAc2 with only Asn or Asn-Phe (derived from soybean agglutinin) was not retained by a C18 reversed-phase column, but could be separated on a GCC with a gradient of 10-45% CH3CN in 30 min. (ii) Ribonuclease B glycopeptides obtained by Pronase digestion could be separated on GCC with a gradient of 10-30% CH3CN, but they were not retained on a C18 reversed-phase column even with water as eluent. (iii) Oligosaccharides released from ribonuclease B by endo-beta-N-acetylglucosaminidase were separated from each other and peptides on GCC with a linear gradient of 10 mM NH4OH to 10 mM NH4OH-12.5% CH3CN in 50 min at 70 degrees C. Silica-based columns do not allow such an alkaline eluent. (iv) Chito-oligosaccharides (DP 1-9) are well separated within 40 min on GCC with a gradient (10 mM NH4OH-10 mM NH4OH with 25% CH3CN) at 50 degrees C. Chito-oligosaccharides could not be separated by high-performance anion exchange columns such as Carbopac PA-1.
π SIMILAR VOLUMES
## Abstract A microchromatographic procedure for highly sensitive analysis of proteins has been developed by using short capillary columns with reverseβphase, ionβexchange, and hydrophobic interaction sorbents. The high analytical mass sensitivity on the level of several nanograms was attained by t
fying enzymes such as phosphotransferases (3) and sul-Oligomannosidic branch isomers (structures diffotransferases (4). In most cases, these biosynthetic fering only in the branch location of a single residue) enzymes remove or add residues to specific branches, which are biosynthetic intermediates
## Recently, Takagaki et al. developed a new method Glycosaminoglycans (heparin, heparan sulfate, derfor the isolation of GAGs with endo-b-xylosidase (5) matan sulfate, chondroitin sulfate, and hyaluronic and fluoro-labeling with 2-aminopyridine (PA). Picoacid) were labeled with a fluorescent reag