High-performance liquid chromatographic chiral separation of β2-homoamino acids
✍ Scribed by Zoltán Pataj; Robert Berkecz; István Ilisz; Aleksandra Misicka; Dagmara Tymecka; Ferenc Fülöp; Daniel W. Armstrong; Antal Péter
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 425 KB
- Volume
- 21
- Category
- Article
- ISSN
- 0899-0042
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Reversed‐phase high‐performance liquid chromatographic methods were developed for the separation of enantiomers of eleven unnatural β^2^‐homoamino acids on chiral stationary phases containing macrocyclic glycopeptides (teicoplanin‐containing Chirobiotic T and T2) or the macrocyclic peptide teicoplanin aglycone (Chirobiotic TAG) as chiral selectors. The effects of the organic modifier, the mobile phase composition, temperature, and the structures of the analytes on the separations were investigated. Separations were carried out at constant mobile phase compositions in temperature range 7–45°C and the changes in enthalpy, Δ(Δ__H__°), entropy, Δ(Δ__S__°), and free energy, Δ(Δ__G__°), were calculated. The −Δ(Δ__G__°) values obtained on the three columns indicated that Chirobiotic TAG, without sugar units, may promote the interactions of the enantiomers of β^2^‐homoamino acids with branched alkyl or aryl side‐chains, whereas for β^2^‐homoamino acids with alkyl side‐chains Chirobiotic T and T2 seem to be more favorable. The elution sequence was determined in some cases and was observed to be R < S. Chirality, 2009. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract High resolution separations of nucleic acids have been performed using high performance capillary electrophoresis (HPCE) and high performance liquid chromatography (HPLC). Electropherograms showing HPCE separations of single and double stranded DNA are presented and compared with HPLC s
A liquid chromatographic ligand exchange chiral stationary phase (CSP) derived from (S)-leucinol was applied in the separation of the enantiomers of 12 beta-amino acids. The resolution was quite successful especially for the enantiomers of beta-amino acids containing aromatic functional group in the
## Abstract Chiral high‐performance liquid chromatography (HPLC) is one of the most powerful tools to prepare enantiopure standards of chiral compounds. In this study, the enantiomeric separation of imidazolinone herbicides, i.e., imazethapyr, imazapyr, and imazaquin, was investigated using chiral
## Abstract Simple procedures are presented for separating the enantiomers of α‐methyldopa, 5‐hydroxytryptophan, tryptophan, triiodothyronine and thyroxine, which require neither special sorbents nor difficult‐to‐obtain or unstable reagents. The method for α‐methyldopa, 5‐hydroxytryptophan and try