Gradient moment nulling in fast spin echo
✍ Scribed by R. Scott Hinks; R. Todd Constable
- Publisher
- John Wiley and Sons
- Year
- 1994
- Tongue
- English
- Weight
- 927 KB
- Volume
- 32
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The fast spin echo sequence combines data from many echo signals in a Carr‐Purcell‐Meiboom‐Gill echo train to form a single image. Much of the signal in the second and later echoes results from the coherent addition of stimulated echo signal components back to the spin echo signal. Because stimulated echoes experience no dephasing effects during the time that they are stored as M, magnetization, they experience a different gradient first moment than does the spin echo. This leads to flow‐related phase differences between different echo components and results in flow voids and ghosting, even when the first moment is nulled for the spin echo signal. A method of gradient moment nulling that correctly compensates both spin echo and stimulated echo components has been developed. The simplest solution involves nulling the first gradient moment at least at the RF pulses and preferably at both the RF pulses and the echoes. Phantom and volunteer studies demonstrate good suppression of flowrelated artifacts.
📜 SIMILAR VOLUMES
## Abstract It has been shown previously that a significant reduction of the acoustic noise in standard, slow magnetic resonance imaging (MRI) sequences is achieved when the gradient pulses have long sinusoidal ramps. An improvement of this method is now presented for fast gradient echo (FLASH) and
## Abstract A method for minimizing field‐echo delay in moment‐nulled gradient‐echo imaging is presented. Even though ramps are accounted for, the analysis yields simple closed‐form solutions. The method is then generalized to the section‐select waveform for three‐dimensional volume imaging and to
## Abstract A fast multi‐section MR imaging technique is described. Gradient‐ and spin‐echo (GRASE) imaging utilizes the speed advantages of gradient refocusing while overcoming the image artifacts arising from static field inhomogeneity and chemical shift. Image contrast is determined by the T2 co
## Abstract The purpose of our study was to perform a prospective comparative analysis of three‐dimensional (3D) steady‐state free precession (SSFP) and two‐dimensional (2D) fast spin‐echo (FSB) imaging in the evaluation of 26 patients with suspected bile duct obstruction. SSFP and highly T2‐weight
## Abstract The purpose of this work is to obtain a better understanding of motion artifacts in fast spin‐echo imaging, in order to eventually identify efficient ways of suppressing them. To do so, the point spread function of a moving point was calculated for fast spin‐echo imaging, and experiment