𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Gradient Elution HPLC of Fats and Oils with Laser Light Scattering Detection

✍ Scribed by Aitzetmüller, K. ;Grönheim, Margaretha


Publisher
John Wiley and Sons
Year
1993
Weight
365 KB
Volume
95
Category
Article
ISSN
0931-5985

No coin nor oath required. For personal study only.

✦ Synopsis


Gradient elution HPLC of oils and fats using reversed-phase HPLC separation system's with laser light-scattering detection are described.

Potential advantages and shortcomings are discussed. Flexible solvent gradient programming permits an adaptation of the system to several types of applications. Using systems of this type the usual solubility problem with long-chain saturated triglycerides can easily be overcome. A useful test-mixture consisting of a series of saturated triglycerides two carbon numbers apart can be obtained by interesterification of hydrogenated palm kernel oil and hydrogenated palm oil. HPLC systems of this type will also permit the simultaneous investigation of diglycerides and triglycerides in oils.


📜 SIMILAR VOLUMES


HPLC assay of underivatized free amino a
✍ das Neves, Higuinaldo J. Chaves ;Morais, Zilda Braga 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 412 KB

## Abstract In this communication the authors report the HPLC SEPARATION OF 20 amino acids without derivatization. Separation was achieved by column swithing using a C‐8 reversed‐phase column and a cationic ion‐exchange column. Detection of the underivatized amino acids was accomplished by means of

Automated on-line HPLC-HRGC with gradien
✍ Munari, F. ;Dugo, G. ;Cotroneo, A. 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 481 KB

## Abstract Citrus essential oil analysis is characterized by the complexity of the separation of all the components which may belong to different classes of compounds and be present in a wide range of concentrations. Capillary GC is the best technique for characterizing the volatile fraction of c

HPLC with light scatter detector and che
✍ Anklam, Elke ;Lipp, Markus ;Wagner, Beate 📂 Article 📅 1996 🏛 John Wiley and Sons ⚖ 477 KB

High performance liquid chromatography equipped with an evaporative light scatter detector was carried out in order to proofthe authenticity of cocoa butter. Signals of 17 characteristic triglycerides have been used to develop two chemometric models. PLS was applied for quantitation while neural net

Simultaneous determination of nucleoside
✍ Shuang Wang; Feng-qing Yang; Kun Feng; De-qiang Li; Jing Zhao; Shao-ping Li 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 301 KB

## Abstract A HPLC coupled with diode array detection (DAD) and evaporative light scattering detection (ELSD) method for qualitative and quantitative analysis of eight nucleosides and nucleobases, three carbohydrates and myriocin in __Cordyceps__ was developed__.__ A Prevail Carbohydrate ES column